Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1014755.1 : SL8500 - Initialized To An Incorrect Length
PreviouslyPublishedAs 221996 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential for Partners and Oracle Support personnel
Applies to:Sun StorageTek SL8500 Modular Library SystemAll Platforms Checked for relevance on 25-May-2011. SymptomsInitialization failedInitialization failure during install Incorrect rail length being reported Changes{CHANGE}Cause{CAUSE}SolutionResolutionReplace defective Handbot Additional Information SL8500-Initialized To An Incorrect Length
Local support team reported during an SL8500 installation the library attempted to initialize incorrectly as a short library. If the defective bot had been replaced, all the HandBots would then agree on a length and the library would have initialized correctly. Another option would be to move one of the functional HandBots to the rail of the originally defective bot. Incorrect rail length, SL8500, 3.11c, Rail length, Short rail initialization, New install, audited Previously Published As STKKB80329 Attachments This solution has no attachment |
||||||||||||
|