Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1014747.1 : VTL - AIX TSM client tape device configuration
PreviouslyPublishedAs 221982 Symptoms Mismatch between TSM element number, drive and RMT Library audit fails TSM had physical tape drive assigned to virtual tape drive Tape serial number mismatch Resolution Resolution information Problem Statement: There are several identifiers associated with each tape drive: � Serial number � assigned to the drive at the factory � Element number � assigned according to where the drive is placed in the library � LUN number � assigned either by software or by setting a parameter or a switch on the drive � Device address � assigned by the operating system on the client system In a VTL, these are augmented by: � � Fibre Channel Target WWPN � The VTL Fibre Channel Port Name for this drive � Fibre Channel Initiator WWPN � The client system Fibre Channel Port Name for this drive All these identities must line up. That is to say, whether the backup software addresses a tape drive by element number or LUN number or device address, the same drive must respond. Method: Maintain a table with all the information for all the tape drives. At a minimum, track the seven pieces of information outlined above. The following pieces of information can be supplied by the VTL console: � � Serial number � assigned to the drive at the factory � Element number � assigned according to where the drive is placed in the library � LUN number � assigned either by software or by setting a parameter or a switch on the drive Attachments This solution has no attachment |
||||||||||||
|