Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1014719.1 : SL8500 - Drive Tray Power Tool Problem with SCSI/Fibre Toolbox and LTO Drives
PreviouslyPublishedAs 221905 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential for Partners and Oracle Support personnel
Applies to:Sun StorageTek SL8500 Modular Library SystemSun StorageTek SL8500 Modular Library System - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 15-Mar-2011. SymptomsUnable to run diagnostics to driveSCSI Toolbox will not run diagnostics Drive will not communicate to a host Changes{CHANGE}Cause{CAUSE}SolutionHow to pull the SL8500 tray cover and disconnect the drive TTI (LDI) cable on the back of the LTO tape drive/s before running the toolbox while the drive tray is powered up using the SL8500 drive tray power tool PN 314831203.