Applies to:Sun StorageTek SL8500 Modular Library SystemAll Platforms Checked for relevance on 2-Feb-2011. SymptomsError from device Code: 501 - Robot can not move on railError 501 Result code 3955 Result code 3955 RC3955 Frequent BOT failures on same rail Error 514 Error from device Code: 514 - Robot needs to be reset Changes{CHANGE}Cause{CAUSE}SolutionResolutionTry to power cycle the affected robot, wait for robot initialization, then run diagnostic routine. If tests are successful, return robot to customer. If failure occurs, perform visual inspection on lower rail looking for abnormal protrusions.Reinitialize robot and rerun tests. If tests are successful, return robot to customer. If tests report errors, replace the Handbot. For replacement procedure, see Replaceable Part Catalog PN96139.