Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1014452.1 : SL8500 - Host IP Address Conflict
PreviouslyPublishedAs 221261
Applies to:Sun StorageTek SL8500 Modular Library SystemAll Platforms Checked for relevance on 2-Feb-2011. SymptomsIPL errorNot being recognized by the HBC Not initializing Library sub-assembly not coming online Initialization error Changes{CHANGE}Cause{CAUSE}SolutionResolutionThe SL8500 host IP address can be configured with an IP address which conflicts with the SL8500 internal LAN resulting in IPL and initialization errors. These errors will potentially prevent some of the library sub-assemblies from coming online to the Library Controller.
The following block of IP addresses should not be configured for the Host IP Interface on the SL8500 HBC card. Consider the following range of IP addresses be reserved for the SL8500 and not for customer use:
10.0.0.0----10.0.225.255
Note: The first usable customer IP address in this range is 10.1.0.0.
This exposure exists all code levels. Conflict, SL8500, IP Address, Drives, S-bot, Host IP address, Library controller, CAP, Host IP Address Conflict in code level 3.31.00 and below., Errors potentially prevent some of the library sub-assemblies from coming online to the Library Controller. Previously Published As STKKB56699 Attachments This solution has no attachment |
||||||||||||
|