Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1014360.1
Update Date:2011-01-18
Keywords:

Solution Type  Problem Resolution Sure

Solution  1014360.1 :   L-Series Library - FSC3E18 - Targeting Error on Library Panel  


Related Items
  • Sun StorageTek L40 Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
  • Sun StorageTek L80 Tape Library
  •  
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L20 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
221060


Applies to:

Sun StorageTek L180 Tape Library
Sun StorageTek L20 Tape Library
Sun StorageTek L40 Tape Library
Sun StorageTek L700 Tape Library
Sun StorageTek L80 Tape Library
All Platforms
Checked for relevance on 18-Jan-2011.

Symptoms

FSC3E18
Targeting error on the library panel for the drive

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Take following actions to resolve issue:

1. Check for lateral movement on the drive(s.)
2. Reseat trays and re-tighten to remove all drive tray movement.
3. Reseat the cables from the drive to the library.
4. Replace the drive.
5. Replace the hand.
6. Replace the:

a. LLC card in L20/40/80.
or
b. MPC in the L180/700.

Product
Sun StorageTek L700 Tape Library
Sun StorageTek L180 Tape Library
Sun StorageTek L40 Tape Library
Sun StorageTek L20 Tape Library
Sun StorageTek L80 Tape Library

L40, L80, L180, L20, L700, FSC3E18
Previously Published As STKKB11447

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback