Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1014360.1 : L-Series Library - FSC3E18 - Targeting Error on Library Panel
PreviouslyPublishedAs 221060
Applies to:Sun StorageTek L180 Tape LibrarySun StorageTek L20 Tape Library Sun StorageTek L40 Tape Library Sun StorageTek L700 Tape Library Sun StorageTek L80 Tape Library All Platforms Checked for relevance on 18-Jan-2011. SymptomsFSC3E18Targeting error on the library panel for the drive Changes{CHANGE}Cause{CAUSE}SolutionTake following actions to resolve issue:1. Check for lateral movement on the drive(s.) 2. Reseat trays and re-tighten to remove all drive tray movement. 3. Reseat the cables from the drive to the library. 4. Replace the drive. 5. Replace the hand. 6. Replace the: a. LLC card in L20/40/80. or b. MPC in the L180/700. Product Sun StorageTek L700 Tape Library Sun StorageTek L180 Tape Library Sun StorageTek L40 Tape Library Sun StorageTek L20 Tape Library Sun StorageTek L80 Tape Library L40, L80, L180, L20, L700, FSC3E18 Previously Published As STKKB11447 Attachments This solution has no attachment |
||||||||||||
|