Solution Type  Problem Resolution Sure

Solution  1014146.1 :   L180/L700 - Unable to set a Hard Port address of 000 using the Drive Menu  


Related Items
  • Sun StorageTek L700 Tape Library
  •  
  • Sun StorageTek L180 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
220470


Applies to:

Sun StorageTek L180 Tape Library
Sun StorageTek L700 Tape Library
All Platforms
Checked for relevance on 31-Jan-2011.

Symptoms

Unable to set Hard port address to 000.
Unable to set hard ALPA from drive menu.
Unable to set a Hard Port address of 000 in the unit from the drive menu.
The library will not accept 000 as hard address for a drive.

Changes

{CHANGE}

Cause

Additional Information
Lowest address allowed to be set is ALPA 001. Engineering changed how they approach the use of address 000.
From Library Engineering on 10/06/2004

Subject: RE: L700 Hard ALPA addressing

Engineering has no plans to write code to allow configuring the L700 as ALPA address 000.

Engineering would have to write a field exceptional code for an account that would allow them to do that. This used to be an allowed address, then we started getting a lot of complaints from customers saying that using address 000 make it look like a fabric attach machine so engineering disallowed it.


Solution

Resolution
The library will not accept 000 as hard address for a drive. Address 001 is the minimum value it will accept. If you previously had a drive with a hard ALPA set with an address of 000, you will be forced to change it to a different hard alpa address. This may require involvement from the customer to change the address at the host. For direct fabric attachment (non-arbitrated loop attachment) enter 126 as the loop-id.
Once the above process has been completed (specifically step 3 above) you can add drives to slots where no drive was installed with no issues. You must press reset on the library and let it re-initialize before the library will recognize the new units.

If the Dynamic World Wide Name feature is required to be enabled at the library, it must be enabled through the CLI port. (Cannot be enabled through the panel)





Tape Drive (all), LTO, L700, L180, SDLT600, ALPA address 000, Drive Menu, Hard ALPA address, 9840, L700 Hard ALPA addressing, 9940, Hard ALPA address 000