Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1014137.1 : VTSS - SLS6684I Ecam Error CC=09 RC=30
PreviouslyPublishedAs 220457 Symptoms SLS6684I RTD ON VTSS RETURNED ECAM ERROR CC=9 RC=30 Resolution Contact Sun Microsystems support so that a case can be opened and files can be downloaded from the VTSS box for diagnosis. ** Internal Fix statement ** Operation was interrupted due to a cache reinitialize operation. 1. Download full set of base files. 2. Review files and determine marginal cache card. 3. Page case out to local support to replace cache card. 4. If any assistance is needed, route case to ST-FE-EDISK. Additional Information Example of error customer will see: SLS6659I VTSS VTSSC11 SIM:00001000060000F90E00008D8200001042000E690000FFFE00004CC000000000 SLS6684I RTD RTD9D31 ON VTSS VTSSC11 RETURNED ECAM ERROR CC=9 RC=30 Product VTSS VTSS, VTCS Previously Published As STKKB71837 Attachments This solution has no attachment |
||||||||||||
|