Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1014137.1
Update Date:2010-07-29
Keywords:

Solution Type  Problem Resolution Sure

Solution  1014137.1 :   VTSS - SLS6684I Ecam Error CC=09 RC=30  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
220457


Symptoms
SLS6684I RTD ON VTSS RETURNED ECAM ERROR CC=9 RC=30

Resolution
Contact Sun Microsystems support so that a case can be opened and files can be
downloaded from the VTSS box for diagnosis.
** Internal Fix statement **

Operation was interrupted due to a cache reinitialize operation.
1. Download full set of base files.
2. Review files and determine marginal cache card.
3. Page case out to local support to replace cache card.
4. If any assistance is needed, route case to ST-FE-EDISK.

Additional Information
Example of error customer will see:
SLS6659I VTSS VTSSC11 SIM:00001000060000F90E00008D8200001042000E690000FFFE00004CC000000000
SLS6684I RTD RTD9D31 ON VTSS VTSSC11 RETURNED ECAM ERROR CC=9 RC=30