Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1014101.1
Update Date:2011-03-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1014101.1 :   SL8500 - Sbot Initialization Failure Due to Rail Terminator Problem  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
220385


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Confidential for Partners and Oracle Support personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 16-Mar-2011.

Symptoms

Robot will not initialize
Sbot fail initialization
Init failure

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution
One of the two blade contacts was not inserted into the mating socket properly. This is not readily apparent but can be found upon close inspection. This affects only the second generation of rail terminators denoted by the use of the HBQ card.
It is also possible to have intermittent rail communication errors if the terminators are not assembled correctly.
The part number for the HBQ terminator card is 313823202.

See the attached for additional information.




Product
Sun StorageTek SL8500 Modular Library System

Internal Comments
Oracle Review 1/19/10, Glen Foley

Rail Terminator, SL8500, Part Number, HBQ terminator card
Previously Published As
STKKB60402

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.