Solution Type  Problem Resolution Sure

Solution  1014076.1 :   SL500 - Not Configuring Drives in DEM  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
220329


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Confidential for Partners and Oracle Support personnel

Applies to:

Sun StorageTek SL500 Modular Library System - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 22-Dec-2010

Symptoms

SL500 is not configuring drives in DEM
Drives are not showing up in configuration
Logs show drives report into the RLC card but do not show in configuration
DEM is not recognized
Missing label
Drives not seen

Log trace all from SL500:

***ERROR::IfmDriveState::executeCommand():Cell DB could not convert the given DRIVE ID (X) into a Logical Address...cellDbStatus==1 log warning warn, 0000, 0000, "Track range: 15590, is short for CEM module, may cause problems."

This is an indication of the label missing as it believes it is a CEM not a DEM.

Changes

NA

Cause

Missing module label.

Solution

Resolution
Check the SL500 has the approriate barcode label inside the DEM, across metal bar.
Refer to Doc 1275819.1 to order labels.
If the bar is missing, contact Tech Support to order the metal bar.

Product
Sun StorageTek SL500 Modular Library System

DEM, Label is missing from DEM module, SL500, Library configuration, Label,


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.