Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1014076.1 : SL500 - Not Configuring Drives in DEM
PreviouslyPublishedAs 220329 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential for Partners and Oracle Support personnel
Applies to:Sun StorageTek SL500 Modular Library System - Version: Not Applicable and later [Release: N/A and later]All Platforms Checked for relevance on 22-Dec-2010 SymptomsSL500 is not configuring drives in DEMDrives are not showing up in configuration Logs show drives report into the RLC card but do not show in configuration DEM is not recognized Missing label Drives not seen Log trace all from SL500: ***ERROR::IfmDriveState::executeCommand():Cell DB could not convert the given DRIVE ID (X) into a Logical Address...cellDbStatus==1
log warning
warn, 0000, 0000, "Track range: 15590, is short for CEM module, may cause problems." This is an indication of the label missing as it believes it is a CEM not a DEM. ChangesNACauseMissing module label.SolutionResolutionCheck the SL500 has the approriate barcode label inside the DEM, across metal bar. Refer to Doc 1275819.1 to order labels. If the bar is missing, contact Tech Support to order the metal bar. Product Sun StorageTek SL500 Modular Library System DEM, Label is missing from DEM module, SL500, Library configuration, Label, Attachments This solution has no attachment |
||||||||||||
|