Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1014045.1 : L700 - Library will not mount tape into drive
PreviouslyPublishedAs 220257
Applies to:Sun StorageTek L700 Tape LibrarySun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L180 Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 31-Jan-2011. SymptomsArm is not moving, stays in front of driveFSC3E2C FSC3E1D FSC3106 Changes{CHANGE}CauseFSC3E1D: Drive detected Media error. FRU's = cart, 79%; drive 20%; logical error 1%.FSC3E2C: Drive wait for load failed. FRU's = drive 90%; logical error 10%. Library operator panel shows drive status as "cartridge in," but drive never fully mounts the tape Bad media resulted in load failure. SolutionResolutionResolution Steps 1. Remove cartridge from drive.
2. Inspect cartridge for any damage. If it is damaged remove cartridge from the library. 3. If cartridge seems to be okay, test by mounting tape on another drive. If problem persists remove cartridge from the library. 4. Test mounting on drive with known good cartridge. Replace drive if this fails. LTO, L700, L180, FSC3E2C, FSC3E1D, FSC3106 Previously Published As STKKB62219 Attachments This solution has no attachment |
||||||||||||
|