Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1013859.1 : L700 / 180 - FSC3208 - Hand Put Failures
PreviouslyPublishedAs 219853
Applies to:Sun StorageTek L180 Tape LibrarySun StorageTek L700 Tape Library All Platforms Checked for relevance on 31-Jan-2011. SymptomsFSC3208Library reporting PUT failures Changes{CHANGE}CauseFSC:3208ERR_CMO_HAND_EMPTY_ON_PUT, Cannot Put the cartridge, the hand is empty. FRU: LOCATION: CONFIDENCE %: HAND ASSY LSM 90 MPC LSM 10 SolutionResolutionTake the following steps to resolve problem:
Robotic Hand, L700, L180 Previously Published As STKKB37984 Attachments This solution has no attachment |
||||||||||||
|