Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1013826.1 : VSM - Message SLS6675E Configuration Error RC=00000004 after Changing VTD Device Addresses
PreviouslyPublishedAs 219772
Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0All Platforms SymptomsErrors received during VTCS initializationVTCS issued SLS6675E during startup SLS6675E VTSS: XXXX VTD: DDDD CONFIGURATION ERROR RC=00000004 SUBSYSTEM INFO ZZZ1/ZZZ2/ZZZ3 ChangesVTD device addresses were changed in the VTCS CONFIG for an existing VTSS.CauseThe VTD addresses were not changed in the HCD / IODEF to reflect the change.SolutionUpdate the HCD / IODEF with the correct VTD device addresses.Previously Published As STKKB32610 Attachments This solution has no attachment |
||||||||||||
|