Asset ID: 1-72-1013826.1
Update Date:2011-06-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1013826.1 :   VSM - Message SLS6675E Configuration Error RC=00000004 after Changing VTD Device Addresses  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
219772


Applies to:

Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0
All Platforms

Symptoms

Errors received during VTCS initialization
VTCS issued SLS6675E during startup
SLS6675E VTSS: XXXX VTD: DDDD CONFIGURATION ERROR RC=00000004 SUBSYSTEM INFO ZZZ1/ZZZ2/ZZZ3

Changes

VTD device addresses were changed in the VTCS CONFIG for an existing VTSS.

Cause

The VTD addresses were not changed in the HCD / IODEF to reflect the change.

Solution

Update the HCD / IODEF with the correct VTD device addresses.