Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1013663.1
Update Date:2011-03-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1013663.1 :   SL8500 - PTP Cable Mis-Routing Causing PTP Initialization Failure  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
219282


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Confidential for Partners and Oracle Support personnel

Applies to:

Sun StorageTek SL8500 Modular Library System
Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 3-Mar-2011.

Symptoms

PTP will not initialize
PTP initialization errors
PTP not working
Cable Mis-routed
Pass thru port does not initialize

Changes

{CHANGE}

Cause

Cable was mis-routed in manufacturing.

Solution

Resolution
Follow these steps to resolve PTP Cable Mis-Routing issue:

 

Field reports and internal audits have confirmed a potential problem associated with the PTP Switch Motor Cable not being routed properly in manufacturing.

 

The mis-routed cable harness is under the mechanism deck and can short against a sharp edge in the metal chassis of the SL8500 PTP bay. The shorted out PTP cable harness can cause PTP initialization errors.

 

Recommendation:

 

Recommend the PTP assembly be pulled out of the SL8500 frame and the PTP bay inside the library be inspected per the attachments; re-route and secured the associated cable harness if necessary as illustrated in the attached.

 

** It should not be necessary to inspect PTP's already installed and in production, the short would typically occur soon after installation and testing.

 

Final Corrective action:

 

Corrective action was implemented 8/2006 in manufacturing and internal audits were completed.

 

Refer to the attached photo examples of error and photo of correct routing.

 


 


PTP, SL8500, Pass through port, Switch Motor Cable, The PTP Switch Motor Cable not being routed properly in manufacturing. PTP cable harness can cause PTP initialization errors, audited, Cable Route