Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1013593.1
Update Date:2011-02-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  1013593.1 :   SL8500 - False "Door Open" Problem - Library Components Rebooting  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
219142


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Confidential for Partners and Oracle Support personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 8-Feb-2011.

Symptoms

Door Open
Reinitialize library
Robotics IPLing at wrong time
Unexpected Reboot
False door open issue
Mechanisms reboot themselves

Changes

{CHANGE}

Cause

Additional Information
The StorageTek[TM] SL8500 modular library system door latch system can cause a false door open condition to be seen. The libraries mechanisms will reboot themselves if this occurs.


Activity from the CAP area can bring out the problem. This is especially true if they are using the old single motor CAP which tends to give the CAP erratic motion and more vibration against the door.



Solution

Resolution
Check door adjustment or intermittent door switch signal path.

Refer to Document: 1017380.1 for door adjustment.

If customer was using the CAP and the library mechanisms re-initialized on their own, you can suspect this problem.  If you suspect this problem, do the following:

1. Look for door open/close events in the HBC event log. The door open and closed events are a type "warning" event not type "error".

Note: If a door open event occurs using the service safety door it will be logged as a "CSE DOOR OPEN" event.

2. If you see these events and no one opened the door you are getting this problem.

Poor door adjustment can cause switch faults that create false door open messages. When this occurs, all power to the external mechanisms is lost.


Perform the following to correct the problem:

1. Check the door adjustment and make any needed adjustments.

2. Check all door switch connections starting at the Fast-on connectors at the switch all the way down to the HBZ push on connectors.

3. Vibrate the door to see if you can bring out the problem.

4. If the door adjustment looks good and it is still failing, consider swapping the switch itself and/or the harness components to the switch.





@ False Door Open, IPL, SL8500, Door open, CAP, Reboot, Misaligned door latch switch can cause false door open messages
Previously Published As STKKB80282

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback