Solution Type  Problem Resolution Sure

Solution  1013408.1 :   SL500 - Inoperative Drive Does Not Report Empty or Full Status Correctly  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
  • Sun Storage L500 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
218736


Applies to:

Sun Storage L500 Tape Library
Sun StorageTek SL500 Modular Library System - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 14-Apr-2011.

Symptoms

False drive status being reported.
If a drive is taken to an inoperative state, the full or empty status from the drive is not correct.
Library status of drive is incorrect.

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution
This problem is in 1409 SL500 library code.

 

Use the "Cartridge Print" CLI command to determine if a cartridge is present in the drive or not. If a cartridge is present, it must be manually removed from the drive.


Library Microcode, SL500, Drive status, Tape Drive
Previously Published As STKKB51485