Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1013278.1 : DLT/SDLT - I/O, Read, Write Errors on Drive - No error condition posted
PreviouslyPublishedAs 218442
Applies to:Sun StorageTek L180 Tape LibrarySun StorageTek L20 Tape Library Sun StorageTek L40 Tape Library Sun StorageTek L700 Tape Library All Platforms Checked for relevance on 29-Dec-2010. SymptomsI/O errorsRead errors Marking the media as bad Write errors No error code posted ChangesnaCausenaSolutionResolutionUse the following steps to resolve problem: 1. Ensure drive is at the current firmware version. 2. Perform R/W test on the drive with a known good tape. 3. If test fails, clean drive with good cleaning cartridge and rerun test. 4. Confirm that the tape involved with the original host failures works OK in another drive. 5. Replace drive if drive fails R/W test and original tape works in another drive. Internal Comments Worn out R/W heads, SDLT, DLT7000, DLT8000, SDLT 220, audited, SDLT 320 Previously Published As STKKB21395 Attachments This solution has no attachment |
||||||||||||
|