Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1013255.1
Update Date:2010-01-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  1013255.1 :   SL8500 - CAP does not rotate freely during Installation.  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
218379


Product
SL8500

Symptoms
CAP does not rotate freely as described in installation manual.
CAP does not turn.

Additional Information
SL8500
Cartridge Access Port
Installation of CAP assembly
Some earlier installation manuals in the CAP installation procedures incorrectly stated that "Step 12" was to "Re-check that the CAP rotates freely".

Resolution
CAP rotation should only occur if a host issues the appropriate "ENTER" command or by hitting the CAP button located on the "Front Operations Panel".

Previously Published As
STKKB41112
Product_uuid
885cbe90-bdf8-11db-8069-080020a9ed93

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback