Symptoms
Customer is unable to browse differential NDMP backups for restore.
Only Full NDMP backups build the client index.  Subsequent level 1-9 backups are not seen in the recovery index.


Resolution
To be able to browse backup history to include incremental entries, 2 variables have to be set to YES on the Sun StorEdge[TM] 5310 array.

Connect to the SE5310 array via telnet, type admin at the [menu] prompt and enter the administrator password!

Then set the following variables to YES :

  1. set ndmp tar.pathnode=yes

  2. set ndmp dump.pathnode=yes

  3. ndmp save

Now differential NDMP backups are correctly recorded in client file indexes.



Relief/Workaround

nwadmin -> Save Set -> recover



Product
Sun StorageTek Enterprise Backup Software 7.4
Sun StorageTek Enterprise Backup Software 7.3
Sun StorageTek Enterprise Backup Software 7.2
Sun StorageTek 5220 NAS Appliance
Sun StorageTek 5310 NAS Appliance

Internal Comments
It has been found on StorEdge Model 5310 NAS Version 4.11 M0 at customer's site, and on StorEdge Model 5220 NAS OS 4.21 in our lab.



enterprise backup, ebs, index, ndmp, incremental, tar.pathnode, dump.pathnode, recover
Previously Published As
91403

Change History
Date: 2007-12-07
User Name: 95826
Action: Approved
Comment: - fixed typos
- verified metadata
- review date ok : 2008-12-04
- checked for TM : fixed TM + product name in title
- checked audience : contract
Publishing
Version: 3
Date: 2007-12-07
User Name: 95826
Action: Accept
Comment:
Version: 0
Product_uuid
b434e696-2433-11dc-9482-080020a9ed93|Sun StorageTek Enterprise Backup Software 7.4
c7e34e81-61f7-11da-bccd-080020a9ed93|Sun StorageTek Enterprise Backup Software 7.3
00db01ec-c70b-11d8-ab52-080020a9ed93|Sun StorageTek Enterprise Backup Software 7.2
a656fa3d-fc97-11da-ac3d-080020a9ed93|Sun StorageTek 5220 NAS Appliance
63654ce5-f88d-11d8-ab63-080020a9ed93|Sun StorageTek 5310 NAS Appliance

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback