Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1013050.1 : VSM - SLS6743E VTSS VTSSxxx FOUND IN INCONSISTENT STATE
PreviouslyPublishedAs 217868 Symptoms Message: SLS6743E VTSS VTSSxxx FOUND IN INCONSISTENT STATE 40/01 SLS6743E Resolution If for any reason a VTSS is removed or replaced and does not keep the identical name, it is necessary to keep the old VTSS name in the VTCS configuration. Example: VTSS NAME=xxxxxx Additional Information All VTVs that were migrated from the old VTSS will still have a flag set with that VTSS name. If the name is not in the configuration it will not be possible to recall the VTV to the new VTSS. Because only the VTSS name is in the VTCS configuration the message SLS6743E VTSSxx FOUND IN INCONSISTENT STATE 40/01 will be generated at HSC/VTCS initialization. A Software Enhancement request has been opened on Pinnacle issue 766594 to change this from an error message to an information message. Product VSM VTCS, Swapped a VSM2 for a VSM3, VSM2, VSM3, Recently removed a VTSS Previously Published As STKKB4704 Product_uuid 5178b7a4-cfef-11da-a933-080020a9ed93 Attachments This solution has no attachment |
||||||||||||
|