Solution Type Problem Resolution Sure Solution 1013006.1 : SunFire[TM] V440 Server: Cable Management Assembly 370-4427-06 interferes with PCI card in PCI slot 0 having external interfaces
PreviouslyPublishedAs 217805 Symptoms The Cable Management Assembly (CMA) that is shipped with the Sun Fire[TM] V440 Server, PN 370-4427-06 can interfere with PCI card located in PCI slot0 that contains external interfacing. PCI cards with connectors on the lower part of the PCI faceplate are prone to interference with CMA. PCI cards such as NICs, SCSI HBA, FCAL HBA, Graphics, etc. with the interface connector(s) located on the lower section of the PCI faceplate, when the cable(s) is attached, can come into contact with the CMA housing when the CMA arm is retracted. PCI cards with higher connector location(s) on the faceplate are least affected. Resolution This is a design limitation on the CMA PN:370-4427-06. Please use other compatible rail kits or get this PN:370-4427-05 instead. The -05 release of the CMA is not affected. Product Sun Fire V440R Server Internal Comments For internal Sun use only. Refer to CR 6394289 Slide rail kit part# 370-4427-06 interfere with the first PCI. This document is written in response to a Kgap request 2740. 370-4427-06, CMA, PCI, slot, interfere Previously Published As 89138 Change History Date: 2007-05-07 User Name: 97961 Action: Approved Comment: - Changed title to comply to the standard format - Converted to STM formatting for better readability - Applied trademarking where it is missing - Made simple sentence/grammatical corrections Version: 3 Date: 2007-05-07 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2007-05-07 User Name: 83378 Action: Approved Comment: Good to Go! Version: 0 Attachments This solution has no attachment |
||||||||||||
|