Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1012979.1 : Sun Enterprise[TM] 10000: Both SSP's reporting as spares.
PreviouslyPublishedAs 217777 Symptoms In very rare instances it is possible that both System Service Processors (SSP) on the Sun Enterprise[TM] 10000 can report that they are spares. Usually this is reported after both hosts are rebooted simultaneously. Resolution
SSP0: diag-level=min SSP1: diag-level=max This will avoid any possible issues of both SSP's attempting to become the main at the same time. Product Sun Enterprise 10000 Server e10k, spare, ssp, failover Previously Published As 88600 Change History Date: 2010-05-05 User Name: Volkmar Grote 117021 Action: Reviewed for Content Team Comment: eliminated "Internal ID use only." Product_uuid 29ddef46-0a18-11d6-92de-ae47474f0f6c|Sun Enterprise 10000 Server Attachments This solution has no attachment |
||||||||||||
|