Solution Type Problem Resolution Sure Solution 1012932.1 : Sun Storage[TM] RAID Arrays Cannot See Drives in User Interface After Powering on the Subsystem
PreviouslyPublishedAs 217727 Symptoms Arrays cannot see disk drives after power on. Symptoms:
Resolution This occurs when the link rate switched is changed to 4Gb/s prior to the power on, and the drives that are in the trays do not support the speed, OR if the speeds do not match the other trays in the storage array. 1. Power off the RAID controller tray, then all of the expansion trays. 2. Check that the link rate switch on all trays for the same drive channel pair are all the same setting.
Note: The Flexline 380 and 6540 have 2 channel pairs Note: The 6580 and 6780 have 4 channel pairs 3. Check whether the channel pair is mixing CSM200 and CSM100/FLA200/FLA300/FLC200 drive trays. This is as simple as looking at the number of drives in the tray. If you have both 16 and 14 drive trays in the same channel pair, you need to have the CSM200 switch settings set to 2Gb/s. No Exceptions. 4. Check the drive types against the switch setting.
For CSM200(16 drive trays), the outer expansion ports are bypassed by the system. You need to use the inner most ports labeled 1A and 1B. 6. After reviewing the link speed settings against your configuration, power on the drive trays, then the RAID tray, and check for your drives. Continued failure to see the drives typically means that you still have a settings mismatch. Contact Sun Services of you require additional help. Product Sun StorageTek 6130 Array Sun StorageTek Flexline 380 Array Sun StorageTek Flexline 240 Array Sun StorageTek Flexline 280 Array Sun StorageTek 6140 Array Sun StorageTek 6540 Array Sun Storage 6580 Array Sun Storage 6780 Array Sun Storage 6180 Array Previously Published As 87964 6140, disks, "not seen", "power up", shutdown Change History Date: 2009-12-02 User: DeCotis Comment: Changed Title. Added Products. Made steps and identification generic to all arrays that can be impacted rather than just the 6140. Date: 2007-05-28 User Name: 95826 Action: Approved Comment: - verified metadata - changed review date to 2008-05-28 - checked for TM - none added - checked audience : contract Publishing Version: 6 Date: 2007-05-28 User Name: 95826 Action: Accept Comment: Version: 0 Date: 2007-05-27 User Name: 156181 Action: Approved Attachments This solution has no attachment |
||||||||||||
|