Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1012745.1 : C4 Tape Library - Unable to Select Some Time Zones on OCP
PreviouslyPublishedAs 217514
Applies to:Sun Storage C4 Tape LibraryAll Platforms Checked for relevance on 3-Jan-2011. SymptomsUsers cannot select any time zones except 'USA Mountain' on Operator Control Panel (OCP) screen, Sun StorageTek[TM] C4 Tape Library.From the Setup screen, use the up and down arrows to highlight "Date and Time" and press Enter. The "Date and Time" screen displays. Then, edit the date and time information but the user cannot change the time zone from 'USA mountain' if the user wants to select others time zones. Changes{CHANGE}Cause{CAUSE}SolutionResolution- V5 cannot set UTC +9 which is Japan timezone. - Multiple timezones are missing from V5 and have been corrected in V11. - Official Sun V11 is scheduled for release either May 23 or June 6th, 2006. Upgrade firmware of Oracle/StorageTek C4 Tape Library to V11-0 or later. Relief/Workaround Ignore the difference of time zone between USA Mountain and your local time. The built-in time zone, standard (UTC-7 hours) and DST (UTC-6 hours) does not affect actual work or functions of the Oracle/StorageTek C4 Tape Library. Additional Information Quantum has released V11-0 firmware to fix the limited function for time zone: http://www.quantum.com/ServiceandSupport/SoftwareandDocumentationDownloads/PX502/Index.aspx Internal Comments esc# 1-16100630 CR# 6406241 time zone, firmware, OCP Previously Published As 85333 Attachments This solution has no attachment |
||||||||||||
|