Solution Type Problem Resolution Sure Solution 1012461.1 : StorADE 2.3 event database grows too large for Fault Signature Analaysis engine; dumps core
PreviouslyPublishedAs 217170 Symptoms The StorADE Alarm database files can grow to such a size that the Fault Signature Analysis engine cannot handle them. The StorADE agent then fails and dumps a core file. A) This problem exists in StorADE version 2.3. B) This problem exists in StorEdge 6920, image version 2.0.5 or earlier. Resolution A) This problem has been fixed in StorADE version 2.4. B) Since there are no pending updates to the StorEdge 6920 2.x.x stream, users must upgrade to the latest StorEdge 6920 3.0.x image. Relief/Workaround Removing the database files will correct this problem. # cd /var/opt/SUNWstade/DATA # rm *db* This workaround will remove the history of events from the system and allow for more manageable viewing and acknowledgment of events in the GUI. Product Storage Automated Diagnostic Environment 2.3 Sun StorageTek 6920 System Internal Comments Escalation: 1-12417885 Bug ID: 6321467 Previously Published As 83200 Change History Date: 2005-12-05 User Name: 25440 Action: Approved Comment: Audience changed to contract per FvF http://kmo.central/howto/FvF.html Publishing. Version: 3 Date: 2005-12-05 User Name: 25440 Action: Accept Comment: Version: 0 Date: 2005-12-05 User Name: 30235 Action: Approved Comment: Clear and to the point. Looks ready for final review. Version: 0 Date: 2005-11-23 User Name: 24176 Action: Add Comment Comment: Seems clear and straightforward; should assist any users who encounter this problem. Are there any particular files whose size users can check to see if this is related to the agent dumping core ? This might be valuable additional information, although it's not crucial. Also (have to nitpick), the word "analysis" is missppelled in the title. No other issues; thanks. Version: 0 Date: 2005-11-16 User Name: 30235 Action: Accept Comment: Version: 0 Date: 2005-11-16 User Name: 115320 Action: Approved Comment: Hello, Please review and send comments to [email protected], [email protected] Thanks, Marc Version: 0 Date: 2005-11-16 User Name: 115320 Action: Created Comment: Version: 0 Product_uuid 8f3abd35-cd09-11d7-9de1-080020a9ed93|Storage Automated Diagnostic Environment 2.3 67794720-356d-11d7-8ef2-ce2ac2bc9136|Sun StorageTek 6920 System Attachments This solution has no attachment |
||||||||||||
|