Solution Type Problem Resolution Sure Solution 1012317.1 : Unable to PXE boot Sun Fire[TM] V40z with LSI MegaRaid SCSI 320-4x adapter installed
PreviouslyPublishedAs 216997 Symptoms The Sun Fire[TM] V40z will not PXE boot Windows 2000 with LSI MegaRaid SCSI 320-4x adapter installed. With card installed, you will see a message similar to the following on the console shortly after pressing F12 to select network boot: Unable to aquire DHCP address . With the card removed, you will not see this message and PXE boot will proceed as normal. Resolution If the V40z has a LSI MegaRaid SCSI 320-4x adapter installed, the firmware version of that adapter needs to be higher than H409. The most current release is version LSI FW 413Z. If this version is not higher than H409, then the V40z is unable to boot via the Broadcom NetXtreme PXE boot with this card installed. Go to the following url for firmware download http://www.lsilogic.com/downloads/selectDownload.do Product Sun Fire V40z Server Sun Fire V20z Server Internal Comments Place Sun Internal-Use Only content here. This content will be published to internal SunSolve only. V40z, stinger, Volume Server, LSI MegaRaid SCSI 320-4x, PXE, network boot, dhcp Previously Published As 80248 Change History Date: 2005-02-10 User Name: 71396 Action: Approved Comment: Performed final review of article. Updated product name and trademarking. Product_uuid 4726b78d-56d2-11d8-9e3a-080020a9ed93|Sun Fire V40z Server 1acc55b3-4b82-11d8-99fc-080020a9ed93|Sun Fire V20z Server Attachments This solution has no attachment |
||||||||||||
|