Symptoms
During installation of N1 Grid PS, the Provisioning Server connects to the
switch, sets the vlan information and then writes to the startup config. It
then issues a Configuring SNP Ports and hangs, then starts all over.
Eventually, the installation fails.
The following is the error message written to the
/var/opt/terraspring/install/run/install.log file:
[2004-02-11 07:02:32][pid=13936] [sev=dbug] Return Value from
'/opt/terraspring/sbin/jexec com.terraspring.drivers.sun.SFBTool -v 4 -I
/dev/fd/0 2>&1' = '7680'
[2004-02-11 07:02:32][pid=13936] [sev=errr] '/opt/terraspring/sbin/jexec
com.terraspring.drivers.sun.SFBTool -v 4 -I /dev/fd/0 2>&1' failed
[2004-02-11 07:02:32][pid=13936] [sev=errr] Blade Switch Setup failed for
Blade System Chassis with System Controller IP '10.99.1.2'. exitcode =
7680, sigpipe =


Resolution
The resolution to this issue is to change the system controller (SC) prompt from
"ssc0/sc" to "ssc0/sc>" (notice the greater than sign). The ">" sign is a requirement
for the N1 Grid PS software to correctly identify the prompt on the SC.
Also, it is critical that the CLI prompt generation be set to manual.
To configure the prompt execute "setupsc" on the SC
The following example only demonstrates updating the SC parameters. This
example assumes that the interfaces were already previously configured.
BL1BOTTOM>setupsc
Entering Interactive setup mode.
Use Ctrl-z to exit & save. Use Ctrl-c to abort.
Do you want to configure the enabled interfaces [y]? n
Do you want to configure the network interface [y]? n
Do you want to configure the managed system interface [y]? n
Do you want to configure the System Controller parameters [y]?
Do you want to enable CLI event reporting via the telnet interface [y]?
Enter the level of events to be displayed over the CLI.
(0 = critical, 1 = major, 2 = minor) [2]:
Enter type of CLI prompt generation for SC and switch.
(0 = none, 1 = manual, 2 = auto) [0]: 0
[Ed NOTE: See that "0" was selected in the above example]
Enter the prompt string [BL1BOTTOM>]: BL1BOTTOM>
[Ed NOTE: See the ">" sign in the above example]
Enter the console escape sequence [#.]:
Enter the CLI timeout (0, 60 - 9999 seconds) [0]:
Should the password entry echo *'s [n]?
Do you want to enable NTP [n]?
BL1BOTTOM>


Product
Sun N1 Provisioning Server 3.1 Software, Blades Edition
Sun Fire B1600 Blade System Chassis

Internal Comments
Mike Olmstead
N1 Specialty Team
Sun PS

N1 Grid PS 3.1 Blades Edition, Installation failure, N1, N1PS
Previously Published As
75226

Change History
Date: 2006-01-19
User Name: 25440
Action: Update Canceled
Comment: *** Restored Published Content *** SSH AUDIT
Version: 0
Date: 2006-01-19
User Name: 25440
Action: Update Started
Comment: SSH AUDIT
Version: 0
Date: 2004-04-13
User Name: 29589
Action: Approved
Comment: checked for dups., minor edits.
Version: 0
Date: 2004-04-13
User Name: 29589
Action: Accepted
Comment:
Version: 0
Date: 2004-04-08
User Name: 106234
Action: Approved
Comment: doc reviewed...passing to next stage
Version: 0
Date: 2004-04-01
User Name: 106234
Action: Accepted
Comment:
Version: 0
Date: 2004-04-01
User Name: 142270
Action: Approved
Comment: This is an issue if SC prompt doesn't contain ">" N1 GPS install fails
Thanks,
Mike Olmstead
Version: 0
Date: 2004-04-01
User Name: 142270
Action: Created
Comment:
Version: 0
Product_uuid
e5df240e-05c2-11d8-84cb-080020a9ed93|Sun N1 Provisioning Server 3.1 Software, Blades Edition
10bec5e4-5865-11d6-9ffc-c65b6cd3fd7d|Sun Fire B1600 Blade System Chassis

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback