Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1012100.1 : Sun Enterprise[TM] 10000:Symptom:SSP 3.5 patch 112261 works on Solaris[TM] 9 despite patch description
PreviouslyPublishedAs 216648 Symptoms Customer appeared to be running into bug 4483879 when trying to DR. Cu was running solaris 9 on the ssp and on the domain, and ssp 3.5. When trying to dr, he was getting the following error: itprd10k3pr-ssp:s1test1% addboard -b 15 -d s1test1 addboard: Domain s1test1 is an NGDR domain addboard: Attempting to acquire DR lock addboard: Attempting to initialize daemon communications Checking environment... Establishing Control Board Server connection... Initializing SSP SNMP MIB... s1test1: System Status - Summary addboard: Testing eligibility of board 15 for attachment DR attach is disabled. Reboot domain with dr-max-mem non-zero to enable. addboard: Attempting to release DR lock addboard: Board or target domain is not eligible for attach addboard: Operation failed itprd10k3pr-ssp:s1test1% Because dr-max-mem is obsolete after Solaris 7, the message indicating that dr-max-mem should be set to a non-zero value should not appear. Resolution The bug 4483879 is fixed in ssp 3.5 patch 112261. This patch description, however lists that its supported for solaris versions up to solaris 8. This is an ssp3.5 specific patch and can be installed on solaris 9 ssp's as well. Currently, the patch description does not reflect that this patch is not OS specific and can be installed on solaris 9 SSP's, as well. PTS-server-esg has indicated that a bug has been filed to eliminate all OS versions from the patch description, but the bug has not yet been completed. Relief/Workaround Despite the patch description for ssp 3.5 patch 112261, it can be installed on an ssp with solaris 9. Product Sun Enterprise 10000 Server ssp, 3.5, patch, solaris, 8, documentation, problem Previously Published As 74318 Change History Date: 2004-02-24 User Name: 13128 Action: Approved Comment: KE quality checklist applied - Publish Version: 0 Date: 2004-02-24 User Name: 13128 Action: Accepted Comment: Version: 0 Date: 2004-02-23 User Name: 101037 Action: Approved Comment: This document needs to be deleted once the document bug has been corrected. Version: 0 Date: 2004-02-23 User Name: 124971 Action: Approved Comment: doc submitted for tech reveiw. Version: 0 Date: 2004-02-23 User Name: 43660 Action: Rejected Comment: Moving back to draft per phone call from author. Version: 0 Date: 2004-02-23 User Name: 124971 Action: Approved Comment: i created this srdb because this patch documentation problem has not been fixed yet and customers may run into this problem. contact me x76523 if you have any questions. Version: 0 Date: 2004-02-23 User Name: 124971 Action: Created Comment: Version: 0 Product_uuid 29ddef46-0a18-11d6-92de-ae47474f0f6c|Sun Enterprise 10000 Server Attachments This solution has no attachment |
||||||||||||
|