Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1011562.1 : C4 Tape Library - How to Solve Character Echo Problem
PreviouslyPublishedAs 215870 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential information provided to Oracle and Partner Service Personnel
Applies to:Sun Storage C4 Tape Library - Version: Not Applicable and later [Release: N/A and later]All Platforms Checked for relevance on 5-Jan-2011. SymptomsWhen a telnet session to Oracle StorageTek[TM] C4 Tape Library is opened, double characters are shown while Username is entered at the login prompt.Changes{CHANGE}Cause{CAUSE}SolutionResolutionProblem Example: # telnet *** PX500 Debug Terminal 45198 *** Connection ID 0 login: sseerrvviicece password:xxxxx PX500> llooggoouutt The solution is to enable LINEMODE after opening the telnet session to the StorageTek C4 Tape Library. The procedure is as below: # telnet *** PX500 Debug Terminal 45198 *** Connection ID 0 (Use escape character '^]' to enter telnet command mode) login: ^] telnet> mode line login: service service password: xxxxx
Note: