Solution Type Problem Resolution Sure Solution 1011222.1 : Sun Fire[TM] E20K and E25K Domain unable to boot from Solaris[TM] 10 Boot image on System Controller running Solaris[TM] 10 and SMS 1.6
PreviouslyPublishedAs 215415 Symptoms Sun Fire[TM] E20K and E25K domains will fail to boot from system controller running Solaris[TM] 10 configured as Jumpstart[TM] server. Following error messages reported while booting from Solaris 10 jumpstart image: ******************************************************************************** WARNING: mountnfs3: pmap_kgetport RPC error 2 (RPC: Can't decode result). WARNING: Unable to mount NFS root filesystem: error 6 Cannot mount root on /pci@1f,0/pci@1,1/network@1,1 fstype nfsdyn panic[cpu0]/thread=180e000: vfs_mountroot: cannot mount root 000000000180b950 genunix:vfs_mountroot+2e8 (800, 200, 0, 185d400, 11e5000, 18ac000) %l0-3: 0000000000001770 0000000000000640 00000000011e5400 00000000000008fc %l4-7: 0000000001833c00 00000000018ae400 0000000000000600 0000000000000200 000000000180ba10 genunix:main+98 (18141a0, 1013800, 18362c0, 18a8c00, 180e000, 1814000) %l0-3: 0000000070002000 0000000000000001 000000000180c000 000000000180e000 %l4-7: 0000000000000001 0000000001074800 0000000000000060 0000000000000000 ***************************************************************************** Resolution For E25K System Controllers running System Management Services (SMS) 1.6 requires the JASS packages and patches installed on Solaris 10. As we know the JASS script disables most of services for security reasons, so make sure to change the following in /etc/system and /etc/hosts.allow file to fix this problem. 1. Remove "set nfssrv:nfs_portmon=1" parameter from /etc/system 2. Add the line "rpcbind: all" in /etc/hosts.allow file Also make sure the NFS 4 version is disabled on the System Controller running Solaris 10. Disabling NFS 4 version can be done by setting the NFS_SERVER_VERSMAX=3 in /etc/default/nfs file. After these changes reboot the System controller where the Solaris jumpstart server is setup. Additional Information It is possible to disable NFS 4 during installation of Solaris 10. There will be a question at the end of Solaris 10 installation "Do you want to enable NFS version 4 ? " Answer "no" to this question. Product Solaris 10 Operating System Sun Fire E25K Server Internal Comments For more details on this problem refer the following Radiance cases. Radiance Case : 37583544 Radiance Case : 10817243 Jumpstart, Install, Solaris 10, nfs, starcat, starkitty, E20K, E25K, SMS, JASS, SST Previously Published As 88045 Change History Date: 2007-05-29 User Name: 95826 Action: Approved Comment: - verified metadata - changed review date to 2008-05- - review date ok : 2008-05-28 - checked for TM - 1 added (missed it last time :-) ) - checked audience : contract Publishing Version: 6 Date: 2007-05-29 User Name: 95826 Action: Accept Comment: Version: 0 Product_uuid 5005588c-36f3-11d6-9cec-fc96f718e113|Solaris 10 Operating System d842dd03-059b-11d8-84cb-080020a9ed93|Sun Fire E25K Server Attachments This solution has no attachment |
||||||||||||
|