Symptoms
Symptom: Under heavy I/O, the Sun Fire[TM] V240 may see the following in /var/adm/messages or on the console:

WARNING: /pci@1c,600000/scsi@2 (glm2):

        SCSI bus MESSAGE IN phase parity error

or

ASC: 0x29 (<vendor unique code 0x29>), ASCQ: 0x2, FRU: 0x0

or

ASC: 0x29 (<vendor unique code 0x29>), ASCQ: 0x3, FRU: 0x0

This usually means that "SCSI bus reset occurred" due to a "SCSI parity error" and an unstable disk drive.



Resolution
To reduce unnecessary SCSI parity errors, add the following three lines to /kernel/drv/glm.conf:

name="glm" parent="/pci@1c,600000"

    unit-address="2"

    scsi-options=0x00101ff8;

Note:  For the unit-address of glm device, check the error message and fill up the unit address accordingly. In the above example the glm unit-address is 2.

This setting disables the Ultra320 SCSI mode of the onboard SCSI.  This setting is necessary because the onboard SCSI chip is an Ultra160 SCSI chip and not an Ultra320 chip.



Product
Sun Fire V240 Server

Internal Comments
Audited/updated 12/03/09 - [email protected], Entry Level SPARC Content Team Member




V240, SCSI bus MESSAGE IN phase parity error, SCSI bus reset, glm.conf
Previously Published As
83279

Change History
Date: 2007-06-12
User Name: 95826
Action: Approved
Comment: - verified metadata
- changed review date to 2008-06-12
- checked for TM - none added
- checked audience : contract
- no further edit required