Solution Type Problem Resolution Sure Solution 1011079.1 : PSH: No Subscriber message (FMD-8000-0W)
PreviouslyPublishedAs 215248 Symptoms The fault message SUNW-MSG-ID: FMD-8000-0W appears. The actions recommended in the message: Run pkgchk-n SUNWfmd does not resolve the problem. Resolution On a Sun Fire[TM] T2000, Sun Fire[TM] T1000, or Sun Ultra[TM] 45 this fault message could result from automated diagnosis software that is available as a patch, but not installed or because automated diagnosis software is not currently available. Validate that the following required patch is installed:
Use the following command to determine current patch levels: # showrev -p | grep Patch: 119578 If the required patch level is not present, install it from SunSolve. Relief/Workaround EVENT-ID: 34d44f55-7ee1-e6b3-b64b-beea3668f204 Cut and paste the EVENT-ID into the following command: # fmdump -e u 34d44f55-7ee1-e6b3-b64b-beea3668f204 TIME CLASS ENA Aug 26 17:33:14.9634 ereport.cpu.ultraSPARC-T1.irc 0x318af6f63d400c01 Contact Sun for support with this information to enable diagnosis of the problem. Product Sun Ultra 45 Workstation Sun Fire T2000 Server Sun Fire T1000 Server Sun SPARC Enterprise T2000 Server Sun SPARC Enterprise T1000 Server PSH, Sun Fire T2000, Sun Fire T1000, No Subscriber, FMD-8000-0W, Sun Ultra 45 Previously Published As 82889 Change History Date: 2009-11-19 User Name: Anthony Rulli Action: Updated Comment: currency check, audited by Anthony Rulli, Entry Level SPARC Content team Date: 2006-10-30 User Name: 29589 Action: Add Comment Comment: This article is part of the PSH initiative. Product_uuid ef0ed4f2-685b-11da-b8a0-080020a9ed93 41b7bc41-2581-11da-99bc-080020a9ed93 79ad78b9-961d-11d9-9adf-080020a9ed93 0e37d2ca-ce95-11db-9135-080020a9ed93 Attachments This solution has no attachment |
||||||||||||
|