Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1010947.1 : Sun StorEdge[TM] Traffic Manager software: primary path automatic failback does not always happen
PreviouslyPublishedAs 215101 Symptoms The Sun StorEdge[TM] Traffic Manager server software(previously known as MPXIO) feature - Automatic Failback configuration, is enabled by setting the variable, auto-failback, to "enable" in the file /kernel/drv/scsi_vhci.conf. There are certain conditions however, such that Automatic Failback to Primary Resolution Sun StorEdge[TM] Traffic Manager software: primary path automatic failback does not always happen When there is a Fibre Channel path state change from OFFLINE to STANDBY, On the other hand, executing luxadm failover to Secondary path, does not mean *** luxadm failover primary <pathname> *** Below, are example messages, of when Fibre Channel Primary path comes back Feb 22 12:09:47 f6800a-dom-a qlc: [ID 686697 kern.info] NOTICE: Qlogic qlc(1): Link ONLINE Feb 22 12:09:48 f6800a-dom-a fp: [ID 517869 kern.warning] WARNING: fp(1): N_x Port with D_ID=20000, PWWN=210100e08b24fb0e reappeared in fabric Feb 22 12:09:48 f6800a-dom-a fp: [ID 517869 kern.warning] WARNING: fp(1): N_x Port with D_ID=20500, PWWN=20030003ba27cf02 reappeared in fabric *** fp driver detected primary path is now back online *** Feb 22 12:09:48 f6800a-dom-a scsi: [ID 243001 kern.info] Target 0x20500: Nonzero peripheral qualifier: Device type=0x1f Peripheral qual=0x1 Feb 22 12:09:48 f6800a-dom-a mpxio: [ID 669396 kern.info] /scsi_vhci/ssd@g60003ba047ced00042182d6b0007ac43 (ssd36) multipath status: optimal, path /ssm@0,0/pci@18,700000/pci@2/SUNW,qlc@5/fp@0,0 (fp1) to target address: 20030003ba27cf02,10 is standby. Load balancing: round-robin Feb 22 12:09:48 f6800a-dom-a scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0): Feb 22 12:09:48 f6800a-dom-a Initiating failover for device ssd (GUID 60003ba047ced00042182d6b0007ac43) *** mpxio automatic failover back to primary path is initiated *** Feb 22 12:09:50 f6800a-dom-a scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0): Feb 22 12:09:50 f6800a-dom-a Failover operation completed successfully for device ssd (GUID 60003ba047ced00042182d6b0007ac43): failed over from secondary to primary Feb 22 12:09:50 f6800a-dom-a scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0): Feb 22 12:09:50 f6800a-dom-a Auto failback operation succeeded for device ssd (GUID 60003ba047ced00042182d6b0007ac43) *** auto failback completed successfully *** Product Sun StorageTek Traffic Manager 3.0 Software Sun StorageTek Traffic Manager 4.4 Software Sun StorageTek Traffic Manager 3.1 Software Sun StorageTek 6120/6320 Controller Firmware 3.2 Sun StorageTek T3 Array Sun StorageTek T3+ Array Internal Comments To enable auto-failback:
Solaris 8 OS requires patch 111412-10 MPXIO, SSTM, SE6320, auto-failback, failback, T3, T4, 6120, failover Previously Published As 80455 Change History Date: 2005-03-03 User Name: 18392 Action: Approved Comment: Added product names, trademarking, did some re-wording and bolding for clarity, corrected spelling, grammar. Version: 3 Date: 2005-03-01 User Name: 18392 Action: Accept Comment: Version: 0 Date: 2005-03-01 User Name: 33935 Action: Approved Comment: Pls proceed with publishing !! Version: 0 Date: 2005-02-22 User Name: 33935 Action: Accept Comment: Version: 0 Date: 2005-02-22 User Name: 87953 Action: Approved Comment: Pls review Version: 0 Attachments This solution has no attachment |
||||||||||||
|