Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1010881.1 : Fujitsu Disk Firmware Upgrade fails with Patch 116815-07 on Sun Storage 3510 Arrays
PreviouslyPublishedAs 215020 The latest Fujitsu disk drive firmware for Sun Storage 3510 Arrays Model MAP3147 FC drives is version 1701 which is found in Patch ID: 116815-07. The latest Seagate disk drive firmware for Sun Storage 3510 Arrays Model ST314680 FC drives is version 0407 found in Patch ID: 114709-07.
Applies to:Sun Storage 3310 SCSI ArraySun Storage 3510 FC Array Sun Storage 3511 SATA Array All Platforms Symptoms{SYMPTOM}Symptoms On Sun Storage 3510 arrays, it was found that Seagate disk firmware upgrades using
14. Type "mload If only one SE3510 array is connected to the host, it will be 15. Download new firmware to all disks at the same time by typing download disk-firmware MAP3147F.1601.fw "MAP3147F SUN146G" ------------------------------------------------------------------- root@srctrg-06 # ./mload SE3510 ############################################################################### Please Enter HOSTNAME OR Changes{CHANGE}Note: The disk drive firmware upgrade was initiated after upgrading the controller firmware to 4.x. Cause{CAUSE}Root cause of Fujitsu disk firmware upgrade failures is due to a problem with the mload binary file in Patch ID: 116815-07. The mload file is the utility to upgrade the disk drive firmware for the Sun Storage 3510 array. SolutionResolution While there is no resolution to this problem, the workaround to upgrade Fujitsu disk drive Relief/Workaround Use the mload utility from Patch ID: 114709-07 with the Change History Date: 2010-11-29 User Name: [email protected] Action: Update and Currency Attachments This solution has no attachment |
||||||||||||
|