Solution  1010552.1 :   Brocade 3800/3900 Switches: Unable to establish an ISL between Brocade Silkworm 3900 and 3800 switches.  


Related Items
  • Brocade 3900 Switch
  •  
  • Brocade 3800 Fabric Switch
  •  
  • Sun Storage 3910 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
214511


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: Migrated distribution from Sun

Symptoms

When attempting to connect an Inter Switch Link (ISL) between a Brocade
Silkwork 3900 and a Brocade Silkwork 3800, the ISL is not established.

islshow on the 3900 reports:
"1: 0 -> (incompatible)"

switchstatusshow on the 3900 will report:
"segmented,(incompatible)"

errdump -a on the 3900 reports an error similar to:
"Switch: 0, Warning FABRIC-SEGMENTED, 3, port 0, ELP rejected by the
other switch"

switchshow on the 3800 reports:
"segmented,incompatible,(Op Mode incompatible)"
On the port used for the ISL.

errDump 0 on the 3800 reports:
"incompatible flow control parameters"



Resolution

Assuming Extended Fabric license is enabled on both the switches.

The Core Switch PID format on the 3800 needs to be changed.

On the 3900 this is set to 1 by default and cannot be changed.
On the 3800 this is set to 0 by default but can be changed.
Changing this parameter will require switch downtime.

Log into the switch

> switchDisable
> configure
Press return until you get to core Switch PID format.
Change that variable to 1.
Press return through the remaining parameters.

Use configShow to verify the change.

> switchEnable

This may effect other Brocade switch models.



Additional Information

Here is a screen capture of the change:

switch:admin> configure

Configure...

 Fabric parameters (yes, y, no, n): [no] y
   Domain: (1..239) [1]
BB credit: (1..27) [16]
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000]
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0]
Disable Device Probing: (0..1) [0]
Suppress Class F Traffic: (0..1) [0]
SYNC IO mode: (0..1) [0]
VC Encoded Address Mode: (0..1) [0]
Core Switch PID Format: (0..1) [0] 1
Per-frame Route Priority: (0..1) [0]
Long Distance Fabric: (0..1) [0]
 Virtual Channel parameters (yes, y, no, n): [no]
Switch Operating Mode (yes, y, no, n): [no]
Zoning Operation parameters (yes, y, no, n): [no]
Arbitrated Loop parameters (yes, y, no, n): [no]
System services (yes, y, no, n): [no]
Portlog events enable (yes, y, no, n): [no]
Committing configuration...done.
switch:admin> configshow
Ethernet addresses: 0:60:69:12:46:d4

Nvram datadata: fei(0,0)host:/usr/switch/firmware e=129.148.202.57:ffffff00
g=129.148.202.248 u=user tn=switch

Type <CR> to continue, Q<CR> to stop: q
diag.postDisable: 0
fabric.domain: 1
fabric.ops.BBCredit: 16
fabric.ops.E_D_TOV: 2000
fabric.ops.R_A_TOV: 10000
fabric.ops.dataFieldSize: 2112
fabric.ops.mode.SeqSwitching: 0
fabric.ops.mode.fcpProbeDisable: 0
fabric.ops.mode.isolate: 0
fabric.ops.mode.longDistance: 0
fabric.ops.mode.noClassF: 0
fabric.ops.mode.pidFormat: 1 < NOTE THE CHANGE
fabric.ops.mode.sync: 0
fabric.ops.mode.tachyonCompat: 0
fabric.ops.mode.unicastOnly: 0
fabric.ops.mode.useCsCtl: 0
fabric.ops.mode.vcEncode: 0
fabric.ops.vc.class.2: 2
fabric.ops.vc.class.3: 3
fabric.ops.vc.config: 0xc0
fabric.ops.vc.linkCtrl: 0
fabric.ops.vc.multicast: 7
fc4.fcIp.address: 0.0.0.0

Type <CR> to continue, Q<CR> to stop:



Product
SAN Brocade 3800 2 GB 16-Port Switch
Brocade SilkWorm 3900 Switch
Brocade 3800 2 GB 16-Port Switch
Sun StorageTek 3900 Series

Internal Comments

Thanks to Paul Mazzarella.


Brocade, Silkworm, 3800, 3900, ISL, segmented, incompatible, Core, Switch, PID
Previously Published As
73554

Change History
Date: 2006-01-23
User Name: 25440
Action: Update Canceled
Comment: *** Restored Published Content *** SSH AUDIT
Version: 0
Date: 2006-01-23
User Name: 25440
Action: Update Started
Comment: SSH AUDIT
Version: 0
Date: 2005-10-31
User Name: 18392
Action: Approved
Comment: Corrected spelling.
Version: 3
Date: 2005-10-31
User Name: 18392
Action: Accept
Comment:
Version: 0
Date: 2005-10-31
User Name: 97195
Action: Approved
Comment: Used Simple Text Markup (STM) to hilight impotant Brocade commands.
Populated the "Technology Areas" box with Switch/Hub.
Changed the " Review Date" to 2006-10-31.

Ready for Final review.
Version: 0
Date: 2005-10-30
User Name: 97195
Action: Accept
Comment:
Version: 0
Date: 2005-10-30
User Name: 100761
Action: Approved
Comment: Problem statement changed from:
When attempting to connect an Inter Switch Link (ISL) between a Brocade
Silkwork 3900 and a Brocade Silkwork 3900, the ISL is not established.
To:
When attempting to connect an Inter Switch Link (ISL) between a Brocade
Silkwork 3900 and a Brocade Silkwork 3800, the ISL is not established.

Added Extended fabirc license check.
Version: 0
Date: 2005-10-30
User Name: 100761
Action: Update Started
Comment: Problem Statement:

Changed from:

When attempting to connect an Inter Switch Link (ISL) between a Brocade
Silkwork 3900 and a Brocade Silkwork 3900, the ISL is not established.

To:

When attempting to connect an Inter Switch Link (ISL) between a Brocade
Silkwork 3900 and a Brocade Silkwork 3800, the ISL is not established.

-- Srinivas.
Version: 0
Date: 2004-01-27
User Name: 13128
Action: Approved
Comment: KE quality checklist applied - Publish
Version: 0
Date: 2004-01-26
User Name: 25675
Action: Approved
Comment: Good Doc, great Examples .
Version: 0
Date: 2004-01-26
User Name: 19533
Action: Approved
Comment: Please review
Version: 0
Date: 2004-01-26
User Name: 19533
Action: Created
Comment:
Version: 0
Product_uuid
5b8e7ce2-11f4-11d7-8cc5-a7ac2a6e4672|SAN Brocade 3800 2 GB 16-Port Switch
f4a61c18-557a-11d7-8ec5-9ccb03c88fd7|Brocade SilkWorm 3900 Switch
12a1cf56-146b-11d7-8078-d16844bae958|Brocade 3800 2 GB 16-Port Switch
04ccc2c2-16a1-11d7-9f9a-f83fdd2e2f1b|Sun StorageTek 3900 Series

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback