![]() | Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1010552.1 : Brocade 3800/3900 Switches: Unable to establish an ISL between Brocade Silkworm 3900 and 3800 switches.
PreviouslyPublishedAs 214511 Oracle Confidential (INTERNAL). Do not distribute to customers Reason: Migrated distribution from Sun Symptoms When attempting to connect an Inter Switch Link (ISL) between a Brocade
islshow on the 3900 reports:
switchstatusshow on the 3900 will report:
errdump -a on the 3900 reports an error similar to:
switchshow on the 3800 reports:
errDump 0 on the 3800 reports: Resolution Assuming Extended Fabric license is enabled on both the switches. The Core Switch PID format on the 3800 needs to be changed. On the 3900 this is set to 1 by default and cannot be changed. Log into the switch
> switchDisable
Use configShow to verify the change. > switchEnable This may effect other Brocade switch models. Additional Information Here is a screen capture of the change: switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] y Domain: (1..239) [1] BB credit: (1..27) [16] R_A_TOV: (4000..120000) [10000] E_D_TOV: (1000..5000) [2000] Data field size: (256..2112) [2112] Sequence Level Switching: (0..1) [0] Disable Device Probing: (0..1) [0] Suppress Class F Traffic: (0..1) [0] SYNC IO mode: (0..1) [0] VC Encoded Address Mode: (0..1) [0] Core Switch PID Format: (0..1) [0] 1 Per-frame Route Priority: (0..1) [0] Long Distance Fabric: (0..1) [0] Virtual Channel parameters (yes, y, no, n): [no] Switch Operating Mode (yes, y, no, n): [no] Zoning Operation parameters (yes, y, no, n): [no] Arbitrated Loop parameters (yes, y, no, n): [no] System services (yes, y, no, n): [no] Portlog events enable (yes, y, no, n): [no] Committing configuration...done. switch:admin> configshow Ethernet addresses: 0:60:69:12:46:d4 Nvram datadata: fei(0,0)host:/usr/switch/firmware e=129.148.202.57:ffffff00 Type <CR> to continue, Q<CR> to stop: q Type <CR> to continue, Q<CR> to stop: Product SAN Brocade 3800 2 GB 16-Port Switch Brocade SilkWorm 3900 Switch Brocade 3800 2 GB 16-Port Switch Sun StorageTek 3900 Series Internal Comments Thanks to Paul Mazzarella. Brocade, Silkworm, 3800, 3900, ISL, segmented, incompatible, Core, Switch, PID Previously Published As 73554 Change History Date: 2006-01-23 User Name: 25440 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT Version: 0 Date: 2006-01-23 User Name: 25440 Action: Update Started Comment: SSH AUDIT Version: 0 Date: 2005-10-31 User Name: 18392 Action: Approved Comment: Corrected spelling. Version: 3 Date: 2005-10-31 User Name: 18392 Action: Accept Comment: Version: 0 Date: 2005-10-31 User Name: 97195 Action: Approved Comment: Used Simple Text Markup (STM) to hilight impotant Brocade commands. Populated the "Technology Areas" box with Switch/Hub. Changed the " Review Date" to 2006-10-31. Ready for Final review. Version: 0 Date: 2005-10-30 User Name: 97195 Action: Accept Comment: Version: 0 Date: 2005-10-30 User Name: 100761 Action: Approved Comment: Problem statement changed from: When attempting to connect an Inter Switch Link (ISL) between a Brocade Silkwork 3900 and a Brocade Silkwork 3900, the ISL is not established. To: When attempting to connect an Inter Switch Link (ISL) between a Brocade Silkwork 3900 and a Brocade Silkwork 3800, the ISL is not established. Added Extended fabirc license check. Version: 0 Date: 2005-10-30 User Name: 100761 Action: Update Started Comment: Problem Statement: Changed from: When attempting to connect an Inter Switch Link (ISL) between a Brocade Silkwork 3900 and a Brocade Silkwork 3900, the ISL is not established. To: When attempting to connect an Inter Switch Link (ISL) between a Brocade Silkwork 3900 and a Brocade Silkwork 3800, the ISL is not established. -- Srinivas. Version: 0 Date: 2004-01-27 User Name: 13128 Action: Approved Comment: KE quality checklist applied - Publish Version: 0 Date: 2004-01-26 User Name: 25675 Action: Approved Comment: Good Doc, great Examples . Version: 0 Date: 2004-01-26 User Name: 19533 Action: Approved Comment: Please review Version: 0 Date: 2004-01-26 User Name: 19533 Action: Created Comment: Version: 0 Product_uuid 5b8e7ce2-11f4-11d7-8cc5-a7ac2a6e4672|SAN Brocade 3800 2 GB 16-Port Switch f4a61c18-557a-11d7-8ec5-9ccb03c88fd7|Brocade SilkWorm 3900 Switch 12a1cf56-146b-11d7-8078-d16844bae958|Brocade 3800 2 GB 16-Port Switch 04ccc2c2-16a1-11d7-9f9a-f83fdd2e2f1b|Sun StorageTek 3900 Series Attachments This solution has no attachment |
||||||||||||
|