Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1010540.1 : Sun StorEdge[TM] 6x20: All Loop cards are locked up
PreviouslyPublishedAs 214491 Symptoms In this particular instance, firmware was upgraded to an unsupported version and then downgraded again. After the downgrade, all the loop cards were locked up and "sys stat" was showing an expansion unit as a VIRTUAL Slave. Unit State Role Partner ----- --------- ------ ------- 1 ONLINE Master 4 2 EXPN UNIT 3 EXPN UNIT 4 ONLINE AlterM 1 5 VIRTUAL Slave 6 EXPN UNIT Resolution 1) telnet into the 6120 2) 6120:> unconfigure u5 (or whichever expansion unit is having the issue) 3) 6120:> reset -y Product Sun StorageTek 6320 System Sun StorageTek 6120 Array Previously Published As 73146 Change History Date: 2005-03-27 User Name: 97961 Action: Approved Comment: Publishing. Version: 3 Date: 2005-03-27 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2005-03-25 User Name: 88218 Action: Approved Comment: Document good Version: 0 Date: 2005-03-22 User Name: 88218 Action: Accept Comment: Version: 0 Date: 2005-03-20 User Name: 97961 Action: Rejected Comment: TR CANNOT BE the same person as the Updater/Author of documents. Moving back to TR phase for other TRs to OK this. - Changed title to follow trademarking conventions. Version: 0 Date: 2005-03-20 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2005-03-19 User Name: 110826 Action: Approved Comment: changed title to look more professional reviewed document for validity Version: 0 Date: 2005-03-19 User Name: 110826 Action: Update Started Comment: reviewing for validity Version: 0 Date: 2003-12-24 User Name: 7058 Action: Approved Comment: OK to publish. Version: 0 Date: 2003-12-24 User Name: 25675 Action: Approved Comment: Reviewed document and looks like great SRDB . Version: 0 Date: 2003-12-19 User Name: 110826 Action: Approved Comment: - Version: 0 Date: 2003-12-19 User Name: 110826 Action: Created Comment: Version: 0 Product_uuid 4de60cc2-a08e-4610-b8bf-6a1881cb59c6|Sun StorageTek 6320 System 2cd2e7d2-2980-11d7-9c3f-c506fe37b7ef|Sun StorageTek 6120 Array Attachments This solution has no attachment |
||||||||||||
|