Solution Type  Problem Resolution Sure

Solution  1010275.1 :   Sun Enterprise[TM] 10000 (E10K): A "boot net" fails on my domain, but it used to work fine.  


Related Items
  • Sun Enterprise 10000 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
214104


Symptoms
I am attempting to boot my domain off the SSP and it is timing out on
the rarp request. I have verified that the SSP is configured correctly
to be a boot server (i.e. /etc/ethers,/etc/hosts, nsswitch.conf and
in.rarpd -a running). What else can be causing this problem?

Resolution
Check eeprom setting on the domain for this variable at the
ok prompt by typing:
printenv local-mac-address?
If set to true, set to false by typing following commands:
setenv local-mac-address? false
reset
and try booting again. If the SSP is indeed setup correctly, with
the original system MAC address, boot net should now work.
This variable is often set to true so more then one interface
can be on the same subnet. The side effect is that the interface
uses its onboard MAC address and not the one supplied by system,
thus RARPs from domain are not answered by the SSP.
NOTE:
Be sure to set this back to true once you have finished with
what ever operation(s) you did while booted over the net.
See the following SunSolve[SM] Documents for more information on setting
multiple MAC address and how this works:
infodoc 17018
What are the steps in configuring more than one Ethernet interfaces
connected to same physical subnet
infodoc 15572
Can I configure two Ethernet interfaces on the subnet?
infodoc 16733
Why do all my ethernet interfaces have the same ether MAC
address?
For more information on booting over the network see "Sun Enterprise 10K
System Hardware Installation and De-Installation Guide" manual.
Also SunSolve infodoc 13328 has good JumpStart[TM] information.


Product
Sun Enterprise 10000 Server

Internal Comments
Since this eeprom change is usually made after the customer
has setup and tested booting from the SSP it is easily overlooked

E10000, boot, net
Previously Published As
18334

Change History
Date: 2004-10-25
User Name: 71396
Action: Approved
Comment: Reviewed, Publishing
Version: 3
Date: 2004-10-19
User Name: 71396
Action: Accept
Comment:
Version: 0
Date: 2004-10-19
User Name: 101037
Action: Approved
Comment: Doc looks fine
Version: 0
Date: 2004-10-19
User Name: 101037
Action: Accept
Comment:
Version: 0
Date: 2004-10-19
User Name: 24462
Action: Approved
Comment: Doc is valid. Updated review date.
Version: 0
Date: 2004-10-19
User Name: 24462
Action: Update Started
Comment: Reviewing Doc
Version: 0
Date: 2003-10-22
User Name: 81292
Action: Approved
Comment: KCCP: changed title layout. OK to publish
Version: 0
Date: 2003-10-19
User Name: 116819
Action: Approved
Comment: ok
Version: 0
Date: 2003-10-17
User Name: 24462
Action: Approved
Comment: Added keywords and changed expiration date
Version: 0
Date: 2003-09-19
User Name: 24462
Action: Updated
Comment:
Version: 0
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : Stephen Taylor
comment : Clean up some areas
date : Jan 9, 1999
Version: 0
Product_uuid
29ddef46-0a18-11d6-92de-ae47474f0f6c|Sun Enterprise 10000 Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback