Asset ID: 1-72-1009558.1
Update Date:2010-10-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  1009558.1 :   Can't change the IP address on Sun StorEdge[TM] T3+ storage array  


Related Items
  • Sun Storage T3+ Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
213182


Symptoms
On a Sun StorEdge[TM] T3+ storage array it was observed that the IP address could not be changed.
The change was attempted from the PSOS prompt.
It was observed that even a temporary change at the EP prompt would not
hold through reboots.
Below are the steps that were performed but were NOT Successful in changing the IP address:
1.  set ip 10.20.33.230 (command at the PSOS prompt)
2.  set (to verify the change)
3.  reset
4.  interrupted the boot cycle, ran set to verify change (still old IP exists)
5.  boot from EP prompt
6.  set command reports the IP as 10.20.33.252 (old IP)


Resolution
If rarp is set to "on", the Sun StorEdge[TM] T3 will always issue a rarp request
and try to get it's IP address from the rarp server.
If there is no answer to the rarp request, it will use the IP address
as defined with the set command.
In order to change the IP address manually, one needs to set rarp to 'off '
and then follow the procedure to change the IP address.
If the rarp server is available, another option is to leave rarp on and edit the host files on the rarp server.
See  Sun StorEdge T3 Administrator's Guide (816-0776-10) for additional
details.


Product
Sun StorageTek T3+ Array

Internal Comments
For internal Sun use only.


written by [email protected] for Storage grp
T3, T3+, ipaddress change, rarp
Previously Published As
83500

Change History
Date: 2006-02-10
User Name: 7058
Action: Approved
Comment: The steps were there. Sorry for the inconvenience. Somehow my screen view truncated them?? I'm still not sure why I could not see them last time I saw the doc. Anyhow, the doc is ready to publish. Spell ck OK, no dups, tags OK..ready to go.
Version: 6
Date: 2006-02-10
User Name: 100752
Action: Approved
Comment: Nita the steps are there, please verify..