Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1009437.1 : Sun StorEdge[TM] 3510 FC Array: Configuring with Crystal+ cards
PreviouslyPublishedAs 213040 Symptoms When a system configured with the Crystal+(375-3030 - a dual channel FC PCI At the OK prompt, a 'probe-scsi-all' command will return: {1} ok probe-scsi-all This command may hang the system if a Stop-A or halt command has been executed. Please type reset-all to reset the system before executing this command. Do you wish to continue? (y/n) y /pci@1d,700000/pci@1/SUNW,qlc@5 Fibre Channel link not ready - Loss of Sync Fibre Channel link down /pci@1d,700000/pci@1/SUNW,qlc@4 *************************** Local Loop Devices *************************** Adapter loopId - 0 /pci@1c,600000/scsi@2,1 If the system is booted, the format command will also not see the device. Resolution The solution is, to reconfigure the data rate of the channel on the Sun Relief/Workaround The temporary workaround, is to manually force a Loop Initialisation Additional Information while bugid# 506386 references Ex500 and HBA# 375-3048, this issue has been Product Sun StorageTek 3510 FC Array Internal Comments See Bug ID: 6256052 power cycle, 3510, missing LUN Previously Published As 81434 Change History Date: 2005-05-20 User Name: 18392 Action: Approved Comment: Added prodcut names, product nouns, did trademarking, moved the rest of the problem description into the problem statement area where it belongs, added a bug reference to internal-only section. Corrected spelling, grammar, did some re-wording and formatting for clarity and readability. Version: 4 Date: 2005-05-18 User Name: 18392 Action: Accept Comment: Version: 0 Date: 2005-05-18 User Name: 124974 Action: Approved Comment: Looks good. Version: 0 Date: 2005-05-18 User Name: 12196 Action: Approved Comment: correction made Version: 0 Date: 2005-05-18 User Name: 124974 Action: Rejected Comment: In the products section, SE3310 LVD drive is selected. I dont see how this SRDB is related to a 3310. Please make the proper changes. Version: 0 Date: 2005-05-05 User Name: 124974 Action: Accept Comment: Version: 0 Date: 2005-05-05 User Name: 12196 Action: Approved Comment: for your review Version: 0 Date: 2005-05-05 User Name: 12196 Action: Created Comment: Version: 0 Product_uuid 58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array Attachments This solution has no attachment |
||||||||||||
|