Solution Type Problem Resolution Sure Solution 1009395.1 : Sun StorEdge[TM] 3310: Some sccli commands run in-band give error: “this operation is only supported on RAID primary controllers”
PreviouslyPublishedAs 212991 Symptoms The Sun StorEdge[TM] 3310 SCSI Array can be managed by a command line interface which comes as a part of a package called SUNWsccli and can be invoked by running "/opt/SUNWsscs/sbin/sccli". The management of Sun StorEdge 3310 SCSI Array can be in-band (using the SCSI interface) or be out of band (using ethernet interface). Some sccli commands run in-band give error: this operation is only supported on RAID primary controllers This error occurs when certain sccli commands are run in-band because all luns mapped to the host are assigned to the secondary controller. Therefore, all sccli commands are being executed by the secondary controller. Note: This does not effect sccli out-of-band or Sun StorEdge[TM] 3510 configurations. In this example the host is attached to ch3. Lun0 (ld2) is assigned to the secondary controller, and mapped to ch3, target 1 (SID=1). With out-of-band sccli: (sccli <ip_address>) sccli> show lun-maps Ch Tgt LUN ld/lv ID-Partition Assigned Filter Map -------------------------------------------------------------- 3 1 0 ld2 0181E2AA-00 Secondary root@buggs / # format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t0d0 <ST34321A cyl 8892 alt 2 hd 15 sec 63> /pci@1f,0/pci@1,1/ide@3/dad@0,0 1. c2t1d0 <SUN-StorEdge3310-0325 cyl 34474 alt 2 hd 64 sec 64> /pci@1f,0/pci@1/pci@2/scsi@5/sd@1,0 Note: t1=target 1 (SID=1) and d0=lun 0 root@buggs / # sccli sccli: selected device /dev/rdsk/c2t1d0s2 [SUN StorEdge 3310 SN#00006C] sccli> show inq Vendor: SUN Product: StorEdge 3310 Revision: 0325 Peripheral Device Type: 0x0 Page 80 Serial Number: 00006C0181E2AA00 Page 83 Logical Unit Device ID: 600C0FF00000000000006C0181E2AA00 Page D0 Target ID: 1 Device Type: Secondary <-- Note Secondary controller sccli> show safte sccli: this operation is only supported on RAID primary controllers sccli> show lun-maps sccli: this operation is only supported on RAID primary controllers sccli> quit Resolution To fix this map at least one lun0 that is assigned to the primary controller to the host channel to which the host is connected. In our example: Through tip session I map lun0 (ld3) assigned to primary controller, to ch3, target 0 (PID=0). root@buggs / # format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t0d0 <ST34321A cyl 8892 alt 2 hd 15 sec 63> /pci@1f,0/pci@1,1/ide@3/dad@0,0 1. c2t0d0 <SUN-StorEdge3310-0325 cyl 43433 alt 2 hd 64 sec 127> /pci@1f,0/pci@1/pci@2/scsi@5/sd@0,0 2. c2t1d0 <SUN-StorEdge3310-0325 cyl 34474 alt 2 hd 64 sec 64> /pci@1f,0/pci@1/pci@2/scsi@5/sd@1,0 Note: t0=target 0 (PID=0) and d0=lun 0 root@buggs / # sccli sccli: selected device /dev/rdsk/c2t0d0s2 [SUN StorEdge 3310 SN#00006C] sccli> show inq Vendor: SUN Product: StorEdge 3310 Revision: 0325 Peripheral Device Type: 0x0 NVRAM Defaults: 325W 3310 v1.40 Bootrecord version: 1.31G Page 80 Serial Number: 00006C7A3D1DCF00 Page 83 Logical Unit Device ID: 600C0FF00000000000006C7A3D1DCF00 Page D0 Target ID: 0 Ethernet Address: 00:C0:FF:80:00:6C Device Type: Primary <-- Note Primary controller Now all sccli in-band commands work: sccli> show lun-maps Ch Tgt LUN ld/lv ID-Partition Assigned Filter Map -------------------------------------------------------------- 3 0 0 ld3 7A3D1DCF-00 Primary 3 1 0 ld2 0181E2AA-00 Secondary sccli> quit Product Sun StorageTek 3310 SCSI Array 3310, sccli, this operation is only supported on RAID primary controllers Previously Published As 80548 Change History Date: 2005-03-21 User Name: 97961 Action: Approved Comment: - Tidied up formatting - Correcting trademarking Version: 4 Date: 2005-03-21 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2005-03-21 User Name: 147406 Action: Approved Comment: The changes suggested have been made. Attachments This solution has no attachment |
||||||||||||
|