Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1009181.1 : Sun Fire[TM] V20z/Sun Fire[TM] V40z can't boot to diags, permission denied
PreviouslyPublishedAs 212711 Symptoms After updating the firmware on a Sun Fire[TM] V20z/Sun Fire[TM] V40z, booting to diags results in permission denied error. Output: localhost $ id uid=2006(sun1) gid=104(service) groups=104(service) localhost $ platform set os state reboot-to-diags start This command may take several minutes. Please be patient. diags: permission denied Unknown error = = 126 localhost $ diags start diags: permission denied Resolution On the server do the following to correct this problem: cd <NSV>/diags/<NSV_VER>/mppc/bin chmod 755 * where "<NSV>" stands for the mount point of your NSV (e.g. /home/nsv), and "<NSV_VER>" stands for the version of the NSV (e.g. 2.1.0.9) that has been mounted. You need to do the following, on the server: cd <NSV>/diags/<NSV_VER>/scripts chmod 777 . The "scripts" sub-directory in the diags directory need be writable by everybody. If this does not happen, then, you will not be able to run any of the platform diagnostics, but can still run voltage, temperature, and fan diagnostics. Additional Information This issue is seen in NSV versions: v20z NSV 2.1.0.16b v40z NSV 2.1.0.16b Product Sun Fire V40z Server Sun Fire V20z Server Internal Comments This issue may be seen in NSV versions: v20z NSV 2.1.0.16c v40z NSV 2.1.0.16c boot, diags, v20z, v40z, NSV Previously Published As 79274 Change History Date: 2004-11-22 User Name: 71396 Action: Approved Comment: Reviewed document, updated trademarks and product names. Publishing. Version: 3 Date: 2004-11-19 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2004-11-19 User Name: 32650 Action: Approved Comment: Great doc, Barry. I added: This issue is seen in NSV versions: v20z NSV 2.1.0.16b v40z NSV 2.1.0.16b Version: 0 Date: 2004-11-19 User Name: 32650 Action: Accept Comment: Version: 0 Date: 2004-11-19 User Name: 101443 Action: Approved Comment: Please review this for accuracy. Version: 0 Date: 2004-11-19 User Name: 101443 Action: Created Comment: Version: 0 Product_uuid 4726b78d-56d2-11d8-9e3a-080020a9ed93|Sun Fire V40z Server 1acc55b3-4b82-11d8-99fc-080020a9ed93|Sun Fire V20z Server Attachments This solution has no attachment |
||||||||||||
|