Solution Type  Problem Resolution Sure

Solution  1009123.1 :   Sun StorEdge[TM] 6320: Flash backup fails with "file system full" error.  


Related Items
  • Sun Storage 6320 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
212614


Symptoms

Backup of the Sun StorEdge[TM] 6320 Service Processor Personality files to flash disk fails to complete.

The following errors are observed in the /var/adm/messages file and the backup script log file:

 [sp0]# /opt/SUNWsefbru/bin/fbr -b
cp: /flash/SP_Personality.tar.Z: No space left on device
 Mar  4 08:08:26 sp0 ufs: [ID 845546 kern.notice]
NOTICE: alloc: /flash: file system full

Since the backup script is executed every two minutes via cron, these warnings continually populate the messages file.



Resolution

The fbr script gets the list of files and directories for backup from /opt/SUNWsefbru/files/backup_list. One of the directories contained in that backup list is:

     /var/opt/SUNWstade/DATA/*

This directory contains relevant StorADE data specific to the Sun StorEdge 6320. It also contains the following subdirectory:

     /var/opt/SUNWstade/DATA/Download/Solution

This subdirectory contains EVERY solution extract performed by the administrator. After multiple solution extracts, the amount of data in the directory will far exceed the 16MB capacity of the flash disk. When this happens, the backup will fail, generating the previously identified error messages.

The solution to the problem is to manually remove EVERYTHING from this directory, including the following subdirectories, files, and links.

    6320.833570ba
extract_6320.833570ba_2004-03-03_105828.tar
log_6320.833570ba_2004-03-03_105828.txt
Extract.tar

Obviously, the names will be slightly different per the host ID and the date and time stamp. The directory contents cannot be emptied with StorADE.

After this, the flash backup should run without any issues. If the problem persists, verify that all files in the backup_list are the appropriate size.



Product
Network Storage
Sun StorageTek 6320 System

Internal Comments

This is Bug 5012671, fixed in MIRE 1.2.5


/flash, fbr, /flash/SP_Personality.tar.Z, flash disk
Previously Published As
74672

Change History
Date: 2005-07-11
User Name: 97961
Action: Approved
Comment: - Tidied up formatting
- Applied/corrected trademarking
Version: 3
Date: 2005-07-11
User Name: 97961
Action: Accept
Comment:
Version: 0
Date: 2005-07-10
User Name: 26402
Action: Approved
Comment: The title of this Doc looks exactly the same as the original Sunsolve version.
Yes, the word "relevant" was mis-spelled - hardly worth a whole review cycle for that !
Made several changes for accuracy and readability.
Added internal reference for Bug.
Version: 0
Date: 2005-06-16
User Name: 26402
Action: Accept
Comment:
Version: 0
Date: 2005-06-16
User Name: 132461
Action: Approved
Comment: Formatting/Title/Spelling
Version: 0
Date: 2005-01-09
User Name: 132461
Action: Update Started
Comment: relevent
Version: 0
Date: 2004-03-16
User Name: C149439
Action: Approved
Comment: Copyedited document.

Gail Waldron
Version: 0
Date: 2004-03-15
User Name: C149439
Action: Accepted
Comment:
Version: 0
Date: 2004-03-10
User Name: 38107
Action: Approved
Comment: Great Work
Version: 0
Date: 2004-03-10
User Name: 73800
Action: Approved
Comment: Let me know when you finish your review.
Version: 0
Date: 2004-03-10
User Name: 73800
Action: Created
Comment:
Version: 0
Product_uuid
aea70032-21a1-11d6-900d-e576a4de8318|Network Storage
4de60cc2-a08e-4610-b8bf-6a1881cb59c6|Sun StorageTek 6320 System

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback