Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1009079.1
Update Date:2011-05-31
Keywords:

Solution Type  Problem Resolution Sure

Solution  1009079.1 :   Sun Fire[TM] V60x/V65x Servers: Temperature Sensor on the Server Gives a False Reading  


Related Items
  • Sun Fire V60x Server
  •  
  • Sun Fire V65x Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>x64 Servers
  •  

PreviouslyPublishedAs
212526


Applies to:

Sun Fire V60x Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire V65x Server - Version: Not Applicable and later    [Release: N/A and later]
All Platforms

Symptoms

Symptoms

The temperature sensor on the server is giving an error that the temperature is too low, but the reading is false.

Cause

Cause

A temperature sensor calibration error existed in older BIOS releases.

Solution

Resolution

Check the BIOS version on the server; it might need to be updated. The BIOS updates can be found at the following location:
   http://www.oracle.com/technetwork/systems/patches/firmware/release-history-jsp-138416.html

If the current BIOS version is older than updates on the page, updates will need to be applied in sequential order until you arrive at the latest release.

Previously Published As 76036

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback