Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1008902.1 : StorADE on Sun StorEdge[TM] 3900 or 6900 Service Processor unable to get Sun StorEdge[TM] T3 serial#/WWN during config_solution
PreviouslyPublishedAs 212250 Symptoms During StorADE discovery of Sun StorEdge[TM] T3+ in Sun StorEdge[SM] 3900, /opt/SUNWstade/bin/config_solution was recommended to be executed. Upon execution of config_solution, the following errors were noticed: root# /opt/SUNWstade/bin/config_solution Enter Model (q=quit): 3960 localhost: -> Error: cannot find the serial# of this T3 -> Error: cannot find the wwn of the first port of this T3 -> Error: cannot find the wwn of the second port of this T3 msp0.localdomain: ERRORS FOUND: Snapshot cannot be saved! Unable to complete discovery of T3+ in StorAde as Snapshot file (/var/opt/SUNWstade/DATA/Solution.golden) was not generated. The following trouble shooting techniques were applied to determine the T3+ and the Service Processor were not the cause of the unsuccessful completion of the config_solution script: - Can successfully ping T3+ arrays from Service Processor. - Can successfully telnet into T3+ arrays from Service Processor. - All .htm files are present in the T3+ /web directory. elemprop.htm enclmap.htm logprop.htm loopinf.htm ofdgoper.htm sysprop.htm voloper.htm frudata.htm fruprop.htm log.htm lun.htm monitor.htm ntp.htm portperf.htm portprop.htm schedule.htm slice.htm sysdata.htm sysdate.htm sysoper.htm sysperf.htm system.htm timeprop.htm vol.htm volperf.htm volprop.htm - The t300.mib file is present in the T3+ /web/snmp directory. - "id read u1" executed on T3+ arrays returned proper serial numbers. - "port list" executed on T3+ arrays returned proper World Wide Numbers. - "reset -y" executed on T3+ and config_solution still reported same errors. - Reboot of Service Processor and config_solution still reported same errors. Resolution The config_solution script utilizes http requests to the T3+ arrays to obtain serial number and WWNs information by browsing the T3+ /web/elemprop.htm file. The elemprop.htm passes http tokens containing T3+ serial numbers and WWNs to config_solution script to generate the snapshot file. Apparently there were problems with the ethernet hub in the 3900 that connects the private network between the Service Processor and T3+ arrays. The private network wasn't allowing any files over 1kB to be transferred. Failure of ftp`ing files over 1kB from the T3+ to service processor confirmed the networking problem. Since elemprop.htm is over 6kB, config_solution was not able to obtain any http tokens as it was unable to access elemprop.htm. Power cycling the ethernet hub resolved the networking problem and allowed files over 1kB to be transferred. The config_solution script now executes with no problems and was able to generate the snapshot file to complete the StorADE T3+ discovery process. Product Sun StorageTek T3+ Array Sun StorageTek T3 Array StorADE 2.2 Storage Automated Diagnostic Environment 2.1 Sun StorageTek 6960 Sun StorageTek 6910 Sun StorageTek 6900 Series Sun StorageTek 3960 Sun StorageTek 3910 Sun StorageTek 3900 Series storade, service processor, sp, config_solution, 6900, 3900, 3910, 6910, 3960, 6960, T3+ Previously Published As 49495 Change History Date: 2003-10-14 User Name: 81292 Action: Approved Comment: great work! ready to publish Version: 0 Date: 2003-10-12 User Name: 127695 Action: Approved Comment: Looks good. Created additional keywords to search on. Version: 0 Date: 2003-10-10 User Name: 25364 Action: Approved Comment: No bug reports could be found on this issue, I even emailed the creator of this SRDB, but did not get a response. I identified the diagnostic steps taken that led to the resolution and changed the wording slightly on the diagnostic steps. Unused headings at the end of the doc can not be removed (click edit button in Voyager to see). Version: 0 Date: 2003-10-08 User Name: 126837 Action: Rejected Comment: Please address bug reports and their fixes, where applicable. Identify the additional diagnosing steps taken at the beginning of the document. Please remove the unused headings at the end of the document. Version: 0 Date: 2003-09-18 User Name: 25364 Action: Approved Comment: Document looks correct. Added config_solution,6900 to Keywords Section. Added Sun StorEdge 3900,6900,3910,3960,6910,6960,Storade 2.1 and 2.2 to Products Section. 45 minutes reviewing document. Version: 0 Date: 2003-09-18 User Name: 25364 Action: Updated Comment: Reviewing doc as part of Knowledge Content Cleanup Project (KCCP). Version: 0 Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : Nita Streit comment : Did Tmark and minor spelling fixes. date : Dec 24, 2002 updated by : Saida Memon comment : I have run into this problem in the past - it was never resolved. So this doc is great. The tech info is helpful and correct. date : Dec 23, 2002 updated by : Saida Memon comment : I have run into this problem in the past - it was never resolved. So this doc is great. The tech info is helpful and correct. date : Dec 23, 2002 updated by : Vincent Tram comment : checking-out of this doc. Probably a kmscreator bug, never checked it out to begin with. date : Dec 16, 2002 updated by : Vincent Tram comment : Article created. date : Dec 12, 2002 updated by : Vincent Tram comment : No comment date : Dec 12, 2002 updated by : Vincent Tram comment : Add properites and permissions and modify title date : Dec 12, 2002 Version: 0 Product_uuid 2a714b10-0a18-11d6-86e2-d56b387d4fbf|Sun StorageTek T3+ Array 2a6d7d50-0a18-11d6-8e0b-f0bd33b24928|Sun StorageTek T3 Array 89723c6f-3c75-4c49-822c-fe446d2a1b5e|StorADE 2.2 f21d0e65-826e-4ff2-ab35-e02ba581611f|Storage Automated Diagnostic Environment 2.1 86b6cc47-00d7-43f1-8efd-81690a8d5b6f|Sun StorageTek 6960 681b08b4-d683-4f9e-b8ba-cbbb87b01d05|Sun StorageTek 6910 09a6d778-16f2-11d7-8802-94885c013b6c|Sun StorageTek 6900 Series 05b0b61b-e1ba-4e07-a932-a782f3b92213|Sun StorageTek 3960 f651ba09-f2d9-4dbc-918c-ad530528e4dc|Sun StorageTek 3910 04ccc2c2-16a1-11d7-9f9a-f83fdd2e2f1b|Sun StorageTek 3900 Series Attachments This solution has no attachment |
||||||||||||
|