Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1008169.1 : C4 - Password Limitations in the C4 Tape Library
PreviouslyPublishedAs 211223
Applies to:Sun Storage C4 Tape LibraryAll Platforms Checked for relevance on 3-Jan-2011. SymptomsThe Sun StorEdge[TM] C4 Tape Library management interface accepts strings of more than 7 characters when setting the password but fails to authenticate when the same password is used when logging in.Changes{CHANGE}Cause{CAUSE}SolutionResolutionUse only the first 7 characters of the password string. For example: When the user "admin" set the password to "cocacola" (8 characters) He will need to login with the following password: "cocacol" (7 characters) If he enters "cocacola" as a password, access is denied. Internal CommentsStorEdge, C4 Previously Published As 85580 Attachments This solution has no attachment |
||||||||||||
|