Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1007803.1
Update Date:2011-04-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1007803.1 :   Sun Storage 3510/3511/3310/3320:"sccli>show-disks" : disk has NONE USED status by RAID 1  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3310 Array
  •  
  • Sun Storage 3511 SATA Array
  •  
  • Sun Storage 3320 SCSI Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
210793


Applies to:

Sun Storage 3310 Array
Sun Storage 3320 SCSI Array
Sun Storage 3510 FC Array
Sun Storage 3511 SATA Array
All Platforms

Symptoms

{SYMPTOM}

Symptoms


Disk in a RAID 1 Logical Drive (LD) is in a NONE USED state after issuing the "sccli>show disks" command.

Problem is often manifested after the customer  has reset the Sun Storage 3310/3320/3510 or 3511 Array, or after a power outage has occurred.

Thu Nov  4 15:02:42 2004
[0181] #1: StorEdge Array SN#7424 Controller NOTICE: controller initialization completed

At this point the disk is given the following status:

Ch Id Size Speed LD Status IDs
----------------------------------------------------------------------
0 0 68.37GB 160MB ld0 ONLINE SEAGATE ST373307LSUN72G 0307
0 1 68.37GB 160MB ld1 ONLINE SEAGATE ST373307LSUN72G 0307
0 2 68.37GB 160MB ld2 ONLINE SEAGATE ST373307LSUN72G 0307
0 3 68.37GB 160MB ld0 ONLINE SEAGATE ST373307LSUN72G 0307
0 4 68.37GB 160MB NONE USED SEAGATE ST373307LSUN72G 0307
0 5 68.37GB 160MB ld2 ONLINE SEAGATE ST373307LSUN72G 0307
0 8 68.37GB 160MB ld0 ONLINE SEAGATE ST373307LSUN72G 0307
0 9 68.37GB 160MB ld1 ONLINE SEAGATE ST373307LSUN72G 0307
0 10 68.37GB 160MB ld2 ONLINE SEAGATE ST373307LSUN72G 0307
0 11 68.37GB 160MB ld0 ONLINE SEAGATE ST373307LSUN72G 0307
0 12 68.37GB 160MB ld1 ONLINE SEAGATE ST373307LSUN72G 0307
0 13 68.37GB 160MB ld2 ONLINE SEAGATE ST373307LSUN72G 0307

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution

IMPORTANT NOTE 


This procedure is to be used ONLY when the LD(s) are in either "DEGRADED" or "OPTIMAL" state. It should NOT be used when the LD is in a "DEAD" or "Fatal Fail" state. Using this procedure for a dead Logical Drive may result in lost data with little or no chance of recovery.


Final Outcome to be :
o ID4 being ONLINE within the Raid1 LD1

Steps to follow :

- go to "view and edit Drives"
- select ID4 (NONE/USED #1)
- select "add Global spare"
- designate ID4 global spare

- go back to the root of the firmware menu (hit Escape)
- go to "view and edit Configuration parameters"
--> select Disk Array Parameters
--> select Rebuild Priority and set it to "Low", "Normal",  "Improved", or "High"

(when selecting "Improved" or "High", discuss with the customer that I/O may be impacted). The value is typically set to normal.

The higher the priority selected, the greater amount of system
resources required. For example, specify low to perform the rebuild
after other firmware processes complete.


- go back to the root of firmware menu (hit Escape)
- go to "view and edit Logical drive"
- select the logical drive that needs to be rebuilt (should be "MISSING DISK")
- choose "rebuild a logical drive"
- watch the "manual rebuild" kick off
- once the rebuild is running go back to root menu



Additional Information
For additional resources see:

Sun StorEdge 3000 Family RAID Firmware 4.2x User's Guide


See Chapter 6 for Drive Status description USED DRV.
The drive was previously configured as part of a logical drive from which it has been removed; it still contains data from this logical drive.

If the "sccli" commands will be used, see the Sun StorEdge 3000 Family CLI 2.5 User Guide

and Technical Instruction 1005062.1   How to use the sccli command to configure and unconfigure Global Spare Disks in Sun Storage 3310, 3320, 3510, and 3511 Arrays.



Change History
Date: 2010-06-28
User Name: [email protected]
Action: Currency & Update

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.