Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1007703.1 : FRU light-emitting diodes (LED) is lit the incorrect status in Maserati or T4 disk.
PreviouslyPublishedAs 210673 Symptoms In some circumstance (e.g. after FRU replacement), Maserati or T4 array's FRU(disk, pcu or controller) shows the incorrect LED, e.g. the disk is showing a blue LED which means "ok to remove" or "not ready", but find that the disk is healthy after issuing a command "fru stat". Even if you try to full power-off/power-on the array. Resolution If the drive is reporting a healthy state in "fru stat" (i.e. STATUS is "Ready", STATE is "Enabled" and PORT1 and PORT2 are both "ready") then the blue led should not be lit on the drive. This can be corrected by the "led" command on the array, and should return the drive to the correct led state for "ok" (blue and amber leds both off). 1. Establish a serial connection or telnet into the array and login as root 2. Run the following command to set LED on the drive u2d09: > led -e 2 -f drive -l ok -i 9 led command usage: led [-e encid] [-f fru_str -l led_str [-i index] | -t] encid Enclosure id or unit id fru_str One of the following: - drive : set the LED status of disk drive - pcu : set the LED status of power cooling unit - controller : set the LED status of controller led_str Display LED status as one of the following: ok, busy, disabled failed, service, locate, nolocate -t Run in test mode Product Sun StorageTek 6120/6320 Controller Firmware 3.2 Sun StorageTek 6920 System Sun StorageTek 6320 System Sun StorageTek 6120 Array 6020, 6120, led, drive, controller, pcu Previously Published As 80371 Change History Date: 2007-10-09 User Name: 7058 Action: Reassign Comment: Publishing this copy. Updates OK to publish Version: 0 Date: 2006-01-23 User Name: 71396 Action: Reassign Comment: Updated products to match Sun System Handbook. Giving the document back to you. Version: 0 Date: 2006-01-23 User Name: 71396 Action: Reassign Comment: Updating document for SSH Audit, will place back in users queue after completed. Version: 0 Date: 2005-04-28 User Name: 154911 Action: Update Started Comment: Very good artical, it's help me a lot Version: 0 Product_uuid 3ad132b5-248c-11d9-8d5c-080020a9ed93|Sun StorageTek 6120/6320 Controller Firmware 3.2 67794720-356d-11d7-8ef2-ce2ac2bc9136|Sun StorageTek 6920 System 4de60cc2-a08e-4610-b8bf-6a1881cb59c6|Sun StorageTek 6320 System 2cd2e7d2-2980-11d7-9c3f-c506fe37b7ef|Sun StorageTek 6120 Array Attachments This solution has no attachment |
||||||||||||
|