Solution Type  Problem Resolution Sure

Solution  1007342.1 :   Sun StorEdge[TM] A3x00/A1000: Raid Manager Commands fail with System_RmHomeDirectory error  


Related Items
  • Sun Storage A3000 Array
  •  
  • Sun Storage A1000 Array
  •  
  • Sun Storage A3500 SCSI Array
  •  
  • Sun Netra st A1000 Array
  •  
  • Sun Storage A3500 FC Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
210130


Symptoms
Anytime a Raid Manager (rm6) command is run, the following error is printed:
No definition for parameter System_RmHomeDirectory - aborting
For example, when launching the GUI:
# /usr/lib/osa/bin/rm6
No definition for parameter System_RmHomeDirectory - aborting
#


Resolution
This message will be given if the directory /etc/osa/locks
is missing.  Sometimes, the directory is inadvertently removed when
cleaning up the lock files in this directory or when removing/renaming the mnf file.  Simply re-create the directory using 'mkdir'. Permissions should be set to 755, owner=root, and group=sys.


Product
Sun StorageTek A1000 Array
Sun StorageTek A3500 FC Array
Netra st A1000 Array
Sun StorageTek A3000
Sun StorageTek A3500 Array

error, command, raid manager
Previously Published As
26744

Change History
Date: 2003-09-26
User Name: 72864
Action: Approved
Comment: Updated title and added product metadata
Version: 0
Date: 2003-09-25
User Name: 110334
Action: Approved
Comment: Adjusted some formating. Approved.
Version: 0
Date: 2003-09-25
User Name: 71676
Action: Approved
Comment: Reviewed-Validated
Expiration date updated
Version: 0
Date: 2003-09-25
User Name: 71676
Action: Updated
Comment:
Version: 0
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : George Bolduc
comment : Not sure why Edward evaluated this since it got pulled off Sunsolve
for no reason.
date : May 30, 2001



updated by : Edward Flodin
comment : procedure is sound, and has been proven.
date : May 17, 2001



updated by : Daniel Caporale
comment : Article created.
date : May 3, 2001



updated by : Daniel Caporale
comment : No comment
date : May 3, 2001



updated by : Chris Kiessling
comment : No comment
date : May 3, 2001



updated by : George Bolduc
comment : Looks OK. Did a bit of reformatting.
date : May 3, 2001
Version: 0
Product_uuid
2a792916-0a18-11d6-8d0a-c3d03933af3c|Sun StorageTek A1000 Array
b648cdf0-efb8-4d4f-93d4-b17c1baf1935|Sun StorageTek A3500 FC Array
49f7ad4a-aa28-47c7-935a-b971312469ea|Netra st A1000 Array
2a7ca41a-0a18-11d6-82f2-e96014c515ea|Sun StorageTek A3000
2a8022d4-0a18-11d6-8043-ee5a180fdb7f|Sun StorageTek A3500 Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback