Solution Type Problem Resolution Sure Solution 1006890.1 : Sun StorEdge[TM] 9900 TrueCopy paircreate fails due to incorrect MTU settings on IP router.
PreviouslyPublishedAs 209555 Symptoms The customer was able to successfully create the RCU link between the MCU and RCU. However, when they attempted to run a paircreate on the entire consistency group (CTG) the command failed immediately from CCI. The first two devices in the CTG showed Copy status: /usr/bin/paircreate -g na3-arch-dgt -f async 5 -vl /usr/bin/pairvolchk -g na3-arch-dgt /usr/bin/pairdisplay -g na3-arch-dgt -fcx After a few minutes the pair status changed to Suspended Error state: /usr/bin/pairdisplay -g na3-arch-dgt -fcx They attempted to create the pair for a single device and the command was not rejected but the same symptoms followed (Copy -> PSUE/SSUS). We had the customer remove the RCU links and recreate them and then attempt to create the pairs from the TC GUI in Storage Navigator. The same symptoms occurred from the GUI as well. The paircreate would start and the first two pairs would show Copy status and then move to PSUE/SSUS status shortly after. None of the other device would even show Copy status, they still showed SMPL. Resolution Analysis of the autodump indicated that there were RCU link issues between the MCU and RCU arrays. SyErr E/F MP# Date Time SSBNo R.SSB Detail Info. C870 9F 06 07/05/14 18:29:40 20583 0 HRC/HODM stat is SUSPEND(statnoneexept) Analysis of the Cisco MD9509 FCIP switches showed that every time the paircreate command was issued the links would fail. The 9509 reported link failures issues between itself and the IP router. Further analysis of the IP router showed that the MTU was to 1500 while the MTU on the Cisco 9509 switch was set to 4000. Once the customer changed the MTU on the IP router to match the setting on the Cisco 9505 the paircreate was able to complete successfully. Product Sun StorageTek 9990V System Sun StorageTek 9990 System Sun StorageTek 9990 Sun StorageTek 9985 System Sun StorageTek 9980 System Sun StorageTek 9970 System Sun StorageTek 9960 System Sun StorageTek 9910 Sun StorageTek 9900V Series Array Internal Comments Sun StorEdge[TM] 9900 TrueCopy paircreate fails due to incorrect MTU settings on IP router. To check the router MTU settings. Cisco: An MTU value cannot be set manually but the PMTU flag can be set (default is on) which will attempt to discover the path MTU along the link. If PMTU is turned off, MTU reverts to 1518 Brocade 7500/FR4-18i/FC4-16i blade: For GE ports on a Silkworm 7500 or an FR4-18i blade in a Silkworm 48000, valid values are from 1500 to 2348. On a FC4-16i in a Silkworm 48000 valid values are from 1500 to 8256. Brocade AP7420: An MTU value cannot be set but 'Jumbo Support' can be turned on (2k/max FC frame) /off. McData 1620/2640: An MTU of between 512 to 4096 (default 1508) can be manually set or use The MTU is but one of many settings that need to be carefully configured for the router link to work correctly. truecopy, paircreate, fails, CCI, HORCM, Raid, Manager, MTU, RCU, LINK, MCU Previously Published As 89536 Change History Date: 2007-05-21 User Name: 31620 Action: Approved Comment: Verified Metadata - ok Verified Keywords - ok Verified still correct for audience - currently set to contract Audience left at contract as per FvF at http://kmo.central/howto/content/voyager-contributor-standards.html Checked review date - currently set to 2008-05-15 Checked for TM - adjusted for TrueCopy product Publishing under the current publication rules of 18 Apr 2005: Version: 3 Date: 2007-05-18 User Name: 31620 Action: Accept Comment: Version: 0 Date: 2007-05-18 User Name: 34660 Action: Approved Comment: Looks good. Just added Internal section for how to identify the MTU for the different routers. Version: 0 Attachments This solution has no attachment |
||||||||||||
|