Solution Type Problem Resolution Sure Solution 1006781.1 : Sun StorEdge[TM] T3+ Release 2.01.03 : "refresh -c" fails while initial charging of battery after replacement.
PreviouslyPublishedAs 209433 Symptoms In some cases, after the battery replacement Sun StorEdge[TM] T3+ with FW Release 2.01.03 shows misleading information on "refresh" command. After the battery replacement if you don't wait upto 12 hrs i.e when batteries are charging it gives confusing output in "refresh command". Here is the details of the problem: You have replaced the T3 battery and issued "refresh -s" command. t3four:/:<3>refresh -s No battery refreshing Task is currently running. PCU1 PCU2 ----------------------------------------------------------------- U1 Low Bat Low Bat Current Time Sun Mar 19 06:28:56 IST 2006 Last Refresh Sat Mar 18 09:06:12 IST 2006 Next Refresh Sat Apr 15 09:06:12 IST 2006 t3four:/:<4> It clearly says no refresh jobs are running and you can see that the batteries are not charging. Next you will try to issue "refresh -c" to start battery charging. But it will fail with following error on syslog: Mar 18 09:45:55 t3four BATD[1]: N: Battery Refreshing cycle starts from this point. Mar 18 09:45:55 t3four BATD[1]: N: u1pcu1:skips battery refresh because the status of this PCU is : BAT not OK Mar 18 09:45:55 t3four BATD[1]: N: u1pcu2:skips battery refresh because the status of this PCU is : BAT not OK Mar 18 09:45:55 t3four BATD[1]: N: Battery Refreshing cycle ends at this point. After the battery replacement, "fru stat" would be still as fault. POWER STATUS STATE SOURCE OUTPUT BATTERY TEMP FAN1 FAN2 ------ ------- --------- ------ ------ ------- ------ ------ ------ u1pcu1 ready enabled line normal fault normal normal normal u1pcu2 ready enabled line normal fault normal normal normal Clearing of warranty date(using .bat -n u<n>pcu<n>) doesn't have any impact on the situation. Resolution Wait about 12 hours to charge the battery, though the refresh command shows misleading information at that time. After you can see battery status is normal on "refresh -s" command, you can expect proper behavior of "refresh -c" command. Check fru stat for PCUs, it would be also correct once you can see battery status is normal.
Note:
115180-08 version 3.1.6 116930 version 3.2.x Product Sun StorageTek T3+ Array Internal Comments See Also: The corresponding section of the Sun System Handbook T3, skips battery refresh because the status of this PCU is : BAT not OK Previously Published As 84970 Change History Date: 2007-11-13 User Name: 7058 Action: Approved Comment: Change reference from sunsolve2 to sunsolve.central in internal only section. Version: 9 Date: 2007-11-13 User Name: 7058 Action: Update Started Comment: fix links Version: 0 Date: 2006-06-26 User Name: 95826 Action: Approved Comment: - fixed typo - verified metadata - changed review date to 2007-06-26 - checked for TM - none added - checked audience : contract Attachments This solution has no attachment |
||||||||||||
|