Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1006781.1
Update Date:2009-01-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1006781.1 :   Sun StorEdge[TM] T3+ Release 2.01.03 : "refresh -c" fails while initial charging of battery after replacement.  


Related Items
  • Sun Storage T3+ Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
209433


Symptoms
In some cases, after the battery replacement Sun StorEdge[TM] T3+ with FW Release 2.01.03 shows misleading information on "refresh" command.

After the battery replacement if you don't wait upto 12 hrs i.e when batteries are charging it gives confusing output in "refresh command".

Here is the details of the problem:

You have replaced the T3 battery and issued "refresh -s" command.

t3four:/:<3>refresh -s
No battery refreshing Task is currently running.
                        PCU1                            PCU2
-----------------------------------------------------------------
U1                      Low Bat                          Low Bat
Current Time            Sun Mar 19 06:28:56 IST 2006
Last Refresh            Sat Mar 18 09:06:12 IST 2006
Next Refresh            Sat Apr 15 09:06:12 IST 2006
t3four:/:<4>

It clearly says no refresh jobs are running and you can see that the batteries are not charging. Next you will try to issue "refresh -c" to start battery charging. But it will fail with following error on syslog:

Mar 18 09:45:55 t3four BATD[1]: N: Battery Refreshing cycle starts from this point.
Mar 18 09:45:55 t3four BATD[1]: N: u1pcu1:skips battery refresh because the status of this PCU is : BAT not OK
Mar 18 09:45:55 t3four BATD[1]: N: u1pcu2:skips battery refresh because the status of this PCU is : BAT not OK
Mar 18 09:45:55 t3four BATD[1]: N: Battery Refreshing cycle ends at this point.

After the battery replacement, "fru stat" would be still as fault.

POWER   STATUS   STATE       SOURCE  OUTPUT  BATTERY  TEMP    FAN1    FAN2
------  -------  ---------   ------  ------  -------  ------  ------  ------
u1pcu1  ready    enabled     line    normal  fault    normal  normal  normal
u1pcu2  ready    enabled     line    normal  fault    normal  normal  normal

Clearing of warranty date(using .bat -n u<n>pcu<n>) doesn't have any impact on the situation.



Resolution
Wait about 12 hours to charge the battery, though the refresh command shows misleading information at that time.

After you can see battery status is normal on "refresh -s" command, you can expect proper behavior of "refresh -c" command.

Check fru stat for PCUs, it would be also correct once you can see battery status is normal.

Note:
If you encounter this issue and you battery status has been cleared according to the information presented above, you should recommend to customer to update T3+ firmware to at least 2.01.06 (patch 112276-13).
Battery handling of T3+ has been improved greatly in firmware version 3.x.x provided in following patches:

115180-08 version 3.1.6
116930    version 3.2.x


Product
Sun StorageTek T3+ Array

Internal Comments
See Also:

The corresponding section of the Sun System Handbook


T3, skips battery refresh because the status of this PCU is : BAT not OK
Previously Published As
84970

Change History
Date: 2007-11-13
User Name: 7058
Action: Approved
Comment: Change reference from sunsolve2 to sunsolve.central in internal only section.
Version: 9
Date: 2007-11-13
User Name: 7058
Action: Update Started
Comment: fix links
Version: 0
Date: 2006-06-26
User Name: 95826
Action: Approved
Comment: - fixed typo
- verified metadata
- changed review date to 2007-06-26
- checked for TM - none added
- checked audience : contract

Attachments